User guide
15
- PROFINET Communication Unit DL-PN1 User’s Manual (SK-1000) -
52 External input status *17 DINT R 0 to 15
53 EEPROM write result *9 DINT R 1
0: Writing
1: Normal termination
2: Abnormal termination
54
Zero shift/Zero shift reset
result
*10 DINT R 1
0: Executing
1: Normal termination
2: Abnormal termination
55 Reset request result *10 DINT R 1
0: Executing
1: Normal termination
2: Abnormal termination
56
System parameter current
state
*11 DINT R 0
Main unit: 0 to 9
Expansion unit: 0 to 1
57 to 63 Reserved for system
64 Group2 Entry count DINT R 17
65 HI setting value (BANK 0) DINT R/W +1.000 -99.999 to +99.999
66 LO setting value (BANK 0) DINT R/W -1.000 -99.999 to +99.999
67 to 69 Reserved for system
70 HI setting value (BANK 1) DINT R/W +1.000 -99.999 to +99.999
71 LO setting value (BANK 1) DINT R/W -1.000 -99.999 to +99.999
72 to 74 Reserved for system
75 HI setting value (BANK 2) DINT R/W +1.000 -99.999 to +99.999
76 LO setting value (BANK 2) DINT R/W -1.000 -99.999 to +99.999
77 to 79 Reserved for system
80 HI setting value (BANK 3) DINT R/W +1.000 -99.999 to +99.999
81 LO setting value (BANK 3) DINT R/W -1.000 -99.999 to +99.999
82 to 95 Reserved for system
96 Group3 Entry Count DINT R 9
97 Key lock function DINT R/W 0
0: Unlock
1: Key lock
98 Bank function *12 DINT R/W 0
0: Switched to bank 0
1: Switched to bank 1
2: Switched to bank 2
3: Switched to bank 3
99 Timing input *13 DINT R/W 0
0: Timing input OFF
1: Timing input ON
100 to
103
Reserved for system
104 Sub display's screen DINT R/W 0
0: Temperature and humidity
1: Temperature
2: Humidity
3: HI setting value
4: LO setting value
5: RV value
105 System parameter settings *11 DINT R/W 0
Main unit: 0 to 9
Expansion unit: 0 to 1
106 to
127
Reserved for system
128 Group4 Entry count DINT R 26
129 Reserved for system
130 Range setting DINT R/W 0
0: NEAR
1: FAR
2: Ib
131 to
132
Reserved for system
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value