133 Averaging DINT R/W 4
0: 1 time
1: 2 times
2: 4 times
3: 8 times
4: 16 times
5: 64 times
6: 256 times
7: 1024 times
8: 4096 times
9: 16384 times
134 Output mode DINT R/W 0
0: N.O.
1: N.C.
135 Reserved for system
136 Hold function setting DINT R/W 0
0: Sample hold
1: Peak hold
2: Bottom hold
3: Absolute value hold
4: Auto peak hold
5: Auto bottom hold
6: Auto absolute value hold
137 Reserved for system
138 Timing input setting DINT R/W 0
0: Level
1: Edge
139 to
140
Reserved for system
141 Hysteresis DINT R/W 0.100 0.000 to 99.999
142 Analog output scaling *14 DINT R/W 0
0: Initial state
1: Free range
143 Analog output upper limit *14 DINT R/W 10.000 -99.999 to 99.999
144 Analog output lower limit *14 DINT R/W -10.000 -99.999 to 99.999
145 External input *15 DINT R/W 0
0: Default
1: User setting
146 External input 1 *15 DINT R/W 0
0: Zero shift input
1: Bank A input
2: Bank B input
3: Not used
147 External input 2 *15 DINT R/W 0
0: Reset input
1: Bank A input
2: Bank B input
3: Not used
148 External input 3 *15 DINT R/W 0
0: Timing input
1: Bank A input
2: Bank B input
3: Not used
149 External input 4 *15 DINT R/W 0
0: Bank A input
1: Bank B input
2: Not used
150 Bank switching method DINT R/W 0
0: Button
1: External input
151 Reserved for system
152
Zero shift value memory
function
DINT R/W 0
0: OFF
1: ON
153 Reserved for system
154 Display columns DINT R/W 0
0: Default
1: 0.001
2: 0.01
3: 0.1
4: 1