User guide
18
- PROFINET Communication Unit DL-PN1 User’s Manual (SK-1000) -
*7 This is 999.8 when the humidity is not acquired correctly.
*8 If a prohibited combination of functions is written, it results in "abnormal setting (1)". 
For details of each function, refer to the SK-1000 Series Instruction Manual.
*9 The result of the "initial reset request" motion command is included in this item.
Regarding Data No. 53 (EEPROM writing result), a "0: writing in progress" status is 
maintained for 2 seconds after completion of the final write command transmission 
to the nonvolatile memory (EEPROM). Writing begins 2 seconds later, and if 
completed normally, the result is "1: successfully completed".
Example:
After every-second write command transmissions, a "0: writing in progress" status is 
established for 2 seconds. A "0: writing in progress" status is maintained for 2 
seconds after completion of the final write command transmission, and writing then 
begins 2 seconds later, with a result of "1: successfully completed".
However, writing begins immediately following a initial reset executed in response to 
a Data No. 5 "initial reset request". A "1: successfully completed" result then occurs 
if all parameters have been saved to the nonvolatile memory (EEPROM) 
approximately 3 seconds later.
• When "zero shift status save" is ON, writing begins immediately for Data No. 1 "zero 
shift execution request" and Data No. 2 "zero shift reset execution request".
*10 The command reads the execution result of the "zero shift execution request" or 
"zero shift reset execution request" whichever was last issued.
*11 By reading the "system parameter current state," the system parameters of the 
sensor amplifier can be checked. The system parameters are comprised of the 
settings of "judgment output/alarm output" polarity and analog output.
The "system parameter" attribute specifies the system parameters which are set 
when the "system parameter set request" is executed by a motion command.
The values to be read or written are specified by translating them to binaries and 
using ON or OFF in each bit of the binaries.
Assume the read data is "006": 
Translating "6" to a binary number gives "0110".
Thus, the sensor amplifier from which the data was read is set to "NPN 
output" and "analog output 1 to 5 V".
*12 This parameter works if "Bank switching method" is set to "button."
*13 These parameters are OFF only if data "0" is written and the wiring is configured to 
turn off external input.
*14 A write control error results if data is rewritten to an expansion unit.
Bit Setting details
0
0: NPN output
1: PNP output
3, 2, 1
000: Analog output OFF
001: 0 to 5V
010: -5 to +5V
011: 1 to 5V
100: 4 to 20mA
Reference
Bit 0: NPN output
011
Bit 3, 2, 1: 1 to 5 V
0