User guide
25
- PROFINET Communication Unit DL-PN1 User’s Manual (SK-1000) -
Types of error and error code
 Error code list
The following error codes may occur in the DL-PN1.
 DL-PN1
Error code Description Cause Actions
0 No error - -
51
Unassigned ID 
error
The main unit assigned no ID 
within 10 seconds after the 
DL-PN1 had been started.
Check if the number of connected sensor 
amplifiers exceeds the maximum number of sensor 
amplifiers that can be connected to the main unit.
 "Types and Number of Connectable Sensor 
Amplifiers" (page 3)
Check the connection with the sensor amplifiers 
and then turn the power on again.
If this error cannot be recovered, contact your 
nearest KEYENCE office.
52
Start-time 
communication 
error
Communication between 
sensor amplifiers ended 
abnormally before ID 
assignment completion.
Check the connection with the sensor amplifiers 
and then turn the power on again.
If this error cannot be recovered, contact your 
nearest KEYENCE office.
53
Unsupported 
sensor amplifier 
connection error
A sensor amplifier not 
supported by the DL-PN1 is 
connected.
Check the model of the connected sensor amplifier 
and remove the sensor amplifier if it is not 
supported by the DL-PN1.
54 Mixed model error
Sensor amplifiers outside the 
specifications have a mixed 
connection.
Check if the models are mixable.
55
Start-time 
communication 
error
ID number assignment is 
successful but communication 
failed during the subsequent 
initial communication.
Check the connection with the sensor amplifiers 
and then turn the power on again.
If this error cannot be recovered, contact your 
nearest KEYENCE office.
56
Current limitation 
error
The number of connected 
sensor amplifiers exceeds the 
allowable range.
Use sensor amplifiers within the allowable range.
57
Communication 
error between 
sensor amplifiers
An error occurred during 
communication between 
sensor amplifiers.
Check if there is a noise source around the DL-PN1.
If the sensor communication indicator is solid red, 
turn the power on again.
100 System error The IP address is incorrect.
Contact your nearest KEYENCE office.
101 System error
A default gateway setting error 
occurred.
102 System error
An attempt to read data in 
EEPROM such as the MAC 
address has failed.
103 System error
An attempt to start the protocol 
stack has failed.
104 System error
An attempt to access 
FlashROM has failed.
150 System error
The number of held IDs is 
incorrect.
151 System error
The number of sensors is 
incorrect.
152 System error An initial read error occurred.