Owner's manual

6-8 Monitor Tab
6-16
GL-RHG-M-NO6-E
Monitoring method Using the Configuration Software
6
OFF information
Point
If the power supplied to the GL-RHG main unit is turned off, the OFF information is erased.
Item Description
(Detected position selection
button)
The beam axis No. which causes the OSSD OFF state is displayed with emphasis in the
"Amount of received light monitoring area".
(Number)
OSSD OFF occurrences are displayed. The history of the most recent OSSD OFF state is
numbered "1" and the oldest occurrence is numbered "20". Up to 20 OSSD OFF occurrences
are displayed.
(History details)
This displays factors that caused the OSSD OFF state. (Detection in detection zone, Error
occurred, etc.)
Time at OSSD OFF This displays the date and time (time of occurrence) when OSSD OFF state occurred.
Detected position This displays the detected beam axis number.
Detected period of time This displays the duration of the detection.
Time at OSSD ON
This displays the date and time (for recovery) when the OSSD is switched from the OFF to ON
state.
When the OSSD state remains off, "OSSDs are in the OFF state." is displayed.
[Update] button This refreshes to the latest OSSD OFF information.