Owner's manual

2-2
GL-RHG-M-NO2-E
Functions and Features
2
2-1 Wiring System
The following three types of wiring systems and the series connection are available in the GL-RHG series.
Wiring system
Reference
Available functions are determined according to the combination of the wiring system and cables.
Refer "2-2 Functions" (page 2-4) for the available function and select the wiring system and
cables.
"Cables" (page 1-2)
"2-2 Functions" (page 2-4)
"4-5 Examples of Wiring" (page 4-7)
Wiring system Optical synchronization system One-line system Wire synchronization system
Wiring diagram
Transmitter Receiver Transmitter Receiver Transmitter Receiver
Advantage
Wiring is not needed between
the transmitter and receiver.
The Transmitter and the
receiver can operate on
different power supplies.
Simplified wiring.
The unit connection cable is
not needed for the transmitter.
All functions of the GL-RHG
are available.
Limitation
The input and output
functions on the transmitter
are not available.
All indicators other than
"Power" are not available on
the transmitter.
The input and output
functions on the transmitter
are not available.
There is a maximum limit for
the total length of cables.
Wiring is needed between the
transmitter and the receiver.
Applicable
cable
Transmitter 5-core cable Series connection cable
7-core cable
11-core cable
Receiver
5-core cable
11-core cable
5-core cable
11-core cable
7-core cable
11-core cable