3-2 Safety Distances
3-7
GL-RHG-M-NO3-E
Installation to a Machine
3
Example 3 :ANSI/RIA R15.06-1999
Safety distance calculation according to ANSI/RIA R15.06-1999 (in a case where the protective
zone is perpendicular to the direction of approach)
Equation: S = [K × (Ts + Tc + Tr)] + Dpf
S : Safety distance (mm)
K : Approach speed of the body or parts of the body into the protective zone (= 63 inch/s)
Ts : Final stop time required when stop control is issued to machine (s)
Tc : Maximum response time of machine's control system (s)
Tr : Maximum response time of the GL-RHG and its interface (s)
Dpf : Additional distance (mm) from the approach factor as in the following figure. This value
varies depending on the GL-RHG detection capability.
ANSI/RIA R15.06-1999 establishes K = 63 inch/s (= 1,600 mm/s) as a minimum speed.
0.0 25
(1.0)
51
(2.0)
76
(3.0)
102
(4.0)
127
(5.0)
152
(6.0)
178
(7.0)
203
(8.0)
64 (2.5)
51 (2.0)
38 (1.5)
25 (1.0)
13 (0.5)
0.0