Owner's manual
4-5 Examples of Wiring
4-10
GL-RHG-M-NO4-E
Wiring
4
One-line system
Transmitter: Series connection cable, Receiver: 5-core cable
(1) PNP output cable
(2) NPN output cable
R1 R2
(+24 V) Brown
(OSSD1) Black
(OSSD2) White
(0 V) Blue
(FE) Grey
Transmitter
Receiver
R1 R2
(+24 V) Brown
(OSSD1) Black
(OSSD2) White
(0 V) Blue
(FE) Grey
Transmitter
Receiver