Owner's manual
4-5 Examples of Wiring
4-12
GL-RHG-M-NO4-E
Wiring
4
Wire synchronization system
Reference
Different core number cables can be used for the transmitter and receiver at the same time.
For example, using the 11-core cable for the transmitter and 7-core cable for the receiver.
Transmitter: 7-core cable, Receiver: 7-core cable
(1) PNP output cable
(2) NPN output cable
R1 R2
PLC
(FE) Grey
(0 V) Blue
(Wait input)) White
(Error output) Black
(+24 V) Brown
(+24 V) Brown
(OSSD1) Black
(OSSD2) White
(0 V) Blue
(FE) Grey
Orange (Synchronization 1)
S2
Transmitter
Receiver
Orange/Black
(Synchronization 2)
R1 R2
PLC
(FE) Grey
(0 V) Blue
(Wait input)) White
(Error output) Black
(+24 V) Brown
S2
(+24 V) Brown
(OSSD1) Black
(OSSD2) White
(0 V) Blue
(FE) Grey
Orange (Synchronization 1)
Orange/Black
(Synchronization 2)
Transmitter
Receiver