User guide

2-8
IG-E
2
Installation and Connection
2-2
Connecting and Mounting the Sensor Head
Notes for mounting
If the mounting distance between the transmitter and receiver is as follows, the optical axis
alignment is not necessary when mounting within the "parallel acceptable range" and "tilt
acceptable range".
IG-010 : 3 to 500 mm
IG-028 : 50 to 500 mm
If the distance is beyond the above ranges, align the optical axis after mounting.
"3-3 Optical Axis Alignment" (page 3-8)
Parallel acceptable range
Tilt acceptable range
Mounting the Sensor Head
Note
The minimum object for detection, linearity and temperature
characteristics in the specifications are values when mounting the
sensor head within the "parallel acceptable range" and "tilt acceptable
range".
"5-1 Specifications" (page 5-2)
Transmitter Receiver
Transmitter Receiver
within ±0.5 mm
within ±0.5 mm
Tilt of transmitter Tilt of receiver
Mounting distance
A B C D
500 mm or less within ±0.0 within ±0.05° within ±1° within ±2°
100 mm or less within ±0.2° within ±0.2° within ±1° within ±2°
Transmitter Receiver
Transmitter Receiver
Mounting distance
A
B
Transmitter Receiver
Transmitter Receiver
Mounting distance
C
D