User guide

3-2
IL-E
3
Basic Operations
3-1
Operation When the Power is Turned on for the First Time
When the amplifier is turned on for the first time after the sensor head is connected, the
initial setting screen appears after a few seconds. Make the initial settings according to the
following procedure.
The initial setting is necessary for both the main unit and the expansion units when units
are added.
4
Make other settings as necessary.
Point
Once the initial setting is completed, the initial setting display will
not appear when the power is turned on the second time or the after.
To change these settings, perform an initial reset.
"3-3 Initial Reset (Initialize)" (page 3-8)
1
Press S/T button to select the polarity of judgment
output and edge check output, and then press [MODE]
button.
[MODE] button
2
Press S/T button to select the type of analog output
and press [MODE] button. (for IL-1000 / IL-1500 only)
"10. Analog Output Scaling" (page 4-27)
[MODE] button
3
After the setting is complete, [end] blinks several
times on the sub display and the main screen
appears.
Power ON
PRP
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
QWV
GO
HOLD CALC
CHECK
Output polarity
Setting value
Description
npn
NPN output
pnp
PNP output
QHH
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
#P.)
GO
HOLD CALC
CHECK
Analog output
Setting value
Description
off
Not output
0-5 u
Analog output after the judgment value (P.V.) is converted to
the range from 0 to 5 V.
-5-5 u
Analog output after the judgment value (P.V.) is converted to
the range from -5 to 5 V.
1-5 u
Analog output after the judgment value (P.V.) is converted to
the range from 1 to 5 V.
ampr
Analog output after the judgment value (P.V.) is converted to
the range from 4 to 20 mA.