3-4 Setting the Tolerance Setting Value
3-11
IL-E
3
Basic Operations
This is the method to directly enter the tolerance setting value (HIGH side setting value,
LOW side setting value).
1
Press the W / X button several times on the main screen. Then display the
HIGH side setting value on the sub display (lower level).
"Sub Display (Lower Level)" (page 3-4)
2
Press S / T button to set the HIGH side setting value.
IL-S025/IL-030/IL-S065/IL-065/IL-100
IL-300/IL-600
IL-2000
3
Press the X
button once and display the LOW side setting value on the sub
display (lower level).
Reference
When setting "HIGH side setting value < LOW side setting value", the
judgment output is as follows.
GO judgment output is not output regardless of the judgment value (P.V.).
(When setting HIGH side setting value = LOW side setting value = judgment value
(P.V.) and setting the hysteresis to 0.000, GO judgment output is turned on.)
When the judgment value (P.V.) goes beyond the HIGH side setting value
and falls below the LOW side setting value, the HIGH judgment output
and LOW judgment output are output at the same time.
Manual Setting
Item Setting range
Default value
HIGH side setting value -99.999 to 99.999 5.000
Item Setting range
Default value
HIGH side setting value -999.99 to 999.99 50.00
Item Setting range
Default value
HIGH side setting value -9999.9 to 9999.9 500.0
GO

LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT

HOLD CALC
CHECK
[HI]
ON
HIGH side setting value

LOW side setting value
[LO]
ON