User guide
3-4 Setting the Tolerance Setting Value
3-13
IL-E
3
Basic Operations
3
Press S / T button to set the tolerance setting width.
4
Press the [SET] button to complete the tolerance tuning.
[set]
blinks on the main display (upper level), and the HIGH side setting value and LOW
side setting value are determined. Then, the display returns to the R.V. screen automatically.
GO
HOLD CALC
CHECK
LASER
BANK
0
1
2
3
HI
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT
Tolerance setting width
Master workpiece P.V.
Setting width
Measurement upper limit value
Measurement lower limit value
LOW side setting value (lower limit)
HIGH side setting value (upper limit)
Master target P.V. (reference value)
IL-S025/IL-030/IL-S065/IL-065/IL-100
IL-300/IL-600
IL-2000
Item Setting range
Default value
Setting width 0.000 to 99.999 0.200
Item Setting range
Default value
Setting width 0.00 to 999.99 2.00
Item Setting range
Default value
Setting width 0.0 to 9999.9 20.0