User guide

4-2
IL-E
4
Setting Various Functions
4-1 Setting Operations
This section explains functions operable on the main screen and functions operable after
the display changes to each setting screen.
Functions Available on the Main Screen
Setting Operations
DIN rail mount type (IL-1000/IL-1050) Panel mount type (IL-1500/IL-1550)
Buttons used
Main screen
Press W or X button.
Switching display on the sub display (lower level) (page 3-4)
The internal measurement value (R.V.), the analog output
value, the HIGH side setting value, the LOW side setting value
or Calculation value (CALC value) is displayed and the setting
can be changed.
3-4 Setting the Tolerance Setting Value (page 3-10)
HIGH side setting value and LOW side setting value are set. The judgment is
made among HIGH/GO/LOW, and the value is displayed and output.
3-5 Zero Shift Function (Shifting the Internal Measurement
Value (R.V.)) (page 3-18)
The internal measurement value (R.V.) can be shifted (offset)
to an arbitrary shift target value.
While pressing down [MODE], press S or T button.
3-6 Bank Function (Registering Multiple Tolerance Setting
Values) (page 3-20)
HIGH side setting value, LOW side setting value, shift target
value, and analog output scaling upper / lower limit value can
be saved in up to four banks and switched.
Press [MODE] and S buttons for approx. 2 seconds.
or
Press [MODE] and T buttons for approx. 2 seconds.
3-7 Key Lock Function (page 3-21)
This function prevents unwanted button operations during measurement.

LASER
BANK
0
1
2
3
HI
GO
LO
R.V.
ANALOG
HI SHIFT
ZERO SHIFT
TIMING
LO
ALIGNMENT

HOLD CALC
CHECK