4-2 Basic Settings and Advanced Settings
4-16
4
Setting Various Functions
IL-E
Sample hold
When the timing input is turned ON, the judgment value (P.V.) is held.
When "Level" is set for "7. Timing Input" (page 4-23)
The judgment value (P.V.) is held only while the timing input is ON.
*1 The main unit (IL-1000/IL-1500) displays the calculation value (CALC value) when the
calculation function is used.
“4-3 Calculation Function” (page 4-42)
When "Edge" is set for "7. Timing Input" (page 4-23)
The judgment value (P.V.) is held while the timing input is ON.
*1 "11. External Input" (page 4-30)
*2 The main unit (IL-1000/IL-1500) displays the calculation value (CALC value) when the
calculation function is used.
“4-3 Calculation Function” (page 4-42)
Display value
Time
Judgment value (P.V.)
Internal measurement value (R.V.)*
1
Timing Input
ON
OFF
Display value
Time
Judgment value (P.V.)
Internal measurement value (R.V.)*
2
Timing Input
ON
OFF
Power ON or
Reset input *
1
After the power is turned on or reset is input, the judgment value (P.V.) is
[- - - - -] until the timing input is first turned ON.