User guide

4-2 Basic Settings and Advanced Settings
4-37
IL-E
4
Setting Various Functions
Switching the bank by the external input
When the Bank A input and Bank B input are set for the external inputs, the bank can be
switched using the external inputs.
"11. External Input" (page 4-30)
"12. Bank Switching Method" (page 4-35)
1
The banks are switched with the ON/OFF combination of the bank A input
and bank B input.
The bank input must be held 20 ms or longer.
"11. External Input" (page 4-30)
The combinations of bank A input and bank B input are shown in the following
table.
2
The bank switching method is switched from button input to external
input.
"12. Bank Switching Method" (page 4-35)
Bank Bank A input Bank B input
Bank 0 OFF OFF
Bank 1 ON OFF
Bank 2 OFF ON ON : Short-circuited
Bank 3 ON ON OFF: Open
Reference
If the external input is not set to bank A or bank B, it is regarded as OFF.
(Example) If only Bank A input is set for the external input, only two patterns
(bank 0 and bank 1) can be switched using the external input.