Instruction Manual
1-5
- IV Series User’s Manual (Field Network) -
Overview of IV Series
Operation of the indicator light
Details on operations of the indicator light are 
shown below.
1 2 3
4 5
1 PWR/ERR
Indicates the power supplying status to the 
sensor and the error status of the sensor.
Green (ON)
 ...... Operating.
Green (Blink)
 .... Setting processing. Operation 
is stopped. Blinks once a 
second.
Red (ON)
 .......... Unrecoverable error has 
occurred.
Red (Blink)
 ....... Recoverable error has 
occurred.
Orange (Blink)
... 
Flash LED has been required on 
the PROFINET communication 
I/O controller. Blinks 4 times 
with a period of about a second.
(OFF)
 ............... Power is not supplied. 
Adjusting the focusing position 
(
manual focus only).
2 OUT
Indicates the comprehensive result.
Green
 ............... Comprehensive result is “OK”.
Red
 .................. Comprehensive result is “NG”.
(OFF)
 ............... Setting processing.
   Standby status until the rst 
judge nishes after starting the 
operation or after switching 
the program number.
Orange (Blink)
 ... 
Indicates the focusing status 
while adjusting the focusing 
position with the blinking speed 
(manual focus type only).
Flash LED has been required on 
the PROFINET communication 
I/O controller. Blinks 4 times 
with a period of about a second.
3 TRIG
Green light lights up (one-shot) according to 
input of the internal or external trigger.
Orange (Blink)
... 
Flash LED has been required on 
the PROFINET communication 
I/O controller. Blinks 4 times 
with a period of about a second.
4 STATUS
Indicates the connecting status to the PC.
Green (ON)
 ...... 
Normally connected with monitor, 
PC, EtherNet/IP communication 
scanner, or PROFINET 
communication I/O controller.
Green (Blink)
 .... IP address has been retrieved 
but the sensor is not correctly 
connected with 
monitor, PC, 
EtherNet/IP communication 
scanner, or PROFINET 
communication I/O controller.
Red (Blink)
 ....... Timeout has occurred at the 
communication with EtherNet/
IP communication scanner.
Red (ON)
 .......... IP address coincides with 
another device.
(OFF)
 ............... IP address is not assigned. 
Not correctly connecting with 
PC.
Orange (Blink)
 .. 
Indicates the focusing status 
while adjusting the focusing 
position with the blinking speed 
(manual focus type only).
5 LINK/ACT
Indicates the linking status within PC or 
Ethernet switch.
Green (ON)
 ...... Normally  linked.
Green (Blink)
 .... Normally linked, and the data 
is sending/receiving.
(OFF)
 ............... 
Sensor is not normally linked.
1