Instruction Manual
3-8
- IV Series User’s Manual (Field Network) -
Cyclic communication setting method
6 
Select [Device comment edit window] 
from the [Edit] menu in KV STUDIO. 
The [Device comment edit] screen will appear. 
  Click [Details]. 
The [Register unit device] screen will appear. 
7 
Make sure that the [IV Series] checkbox is 
ON 
 in the [Select unit] eld, and then 
click the [Reg] button. 
8 
Select [PLC Transfer] from the [Monitor/
Simulator] menu of KV STUDIO. 
Rockwell Automation Control Logix 
series settings
This following explains the setting method when 
using a Control Logix PLC. 
1 
Select the EtherNet/IP communication unit 
to be connected with the IV series in 
the I/O conguration of RsLogix5000, and 
then right-click to select [New Module]. 
The [Select Module] screen will appear. 
2 
Click the [+] button next to Communications, 
and then select EtherNET-MODULE (Generic 
Ethernet Module) and click the [OK] button. 
The [New Module] screen will appear. 
3
Cyclic communication