Instruction Manual
5-3
- IV Series User’s Manual (Field Network) -
Data I/O communication setting method
This following explains the setting method when 
using the data I/O communication. 
To control the IV series using the PROFINET 
communication, select [Network connection] for the 
sensor connection setting. When connected directly, the 
eld network settings will be greyed out and disabled.
The PROFINET function will stop if the scanner is 
connected directly while the PROFINET function 
is in use. To use the PROFINET function again, 
you need to restart the sensor. 
If you have modied the protocol settings, the 
connection with the sensor will be terminated and 
then restarted. 
Setting the IV series
You can congure the following settings for the IV series 
using the monitor (IV-M30) or IV-Navigator (IV-H1). 
When settings on the monitor (IV-M30)
Set the eld network settings of the sensor to 
[PROFINET]. 
1 
Touch the [Sensor expansion settings] 
button on the sensor settings menu screen. 
2 
Touch the [Environment setting] button, 
followed by the [Network expansion 
setting] button. 
3 
Touch the [Settings] button for the eld 
network. 
4 
Select [PROFINET] for the protocol. 
5 
Select [Enabled] if you wish to enable the 
data handshake control. 
If the protocol is set to [Disabled], the 
settings will be greyed out and disabled. 
If data handshake control has been set 
to [Enabled], the status result will not be 
updated until [Result acquisition complete 
notice] (Address2, Bit0 of Command Control) 
is input. 
 “Operating procedure of the data I/O 
communication” (Page 5-32)
6 
Once you have nished conguring the 
settings, touch the [OK] button. 
Data I/O communication setting method