Instruction Manual
5-14
- IV Series User’s Manual (Field Network) -
Data I/O communication setting method
17  
Select [Station] - [Save and Compile] in 
the [HW Cong] window, and save the 
settings. 
18 
Select [PLC] - [Download] in the [HW 
Cong] window to download the settings 
to the CPU. 
19 
Set the CPU mode switch to “RUN”. 
If the connection is successful, the RUN LED 
of the CPU will light in green and the data I/O 
communication will become enabled. 
By default, [Size of the process-image input 
area] is set to “128”. 
To be able to access the addresses after 
address 128, expand the setting as shown 
below. 
Modifying [Size of the process-image input 
area] may affect the scan time of the PLC. 
Make sure to conduct a thorough verication 
before the operation. 
5
Data I/O communication