Owner manual
6-2
Items to be Set in the Environment Setting
This section describes the setting items such as the RS-232C interface,
program, and interface language.
Following items can be set in the environment setting.
The items, default values of the factory setting, and options are listed below.
Items in [XXXX] are displayed on the screen.
The environment setting parameters cannot be saved on program basis.
RS-232C interface ( page 6-5)
Program ( page 6-6)
Note
List of Default Values
Environment Setting Items
E LT-9001-IM
Environment Settings
6
Chapter
Item Description
RS-232C RS-232C Performs settings of baud rate, parity, stop bit, data
length, and data mode for the interface.
Program Settings for changing the program setting, copying program
settings, and resetting the program to the default settings.
Beep sound Set the beep sound that is heard when a button on the remote
control console is pressed.
Interface language Selects the language displayed on the screen.
SPAN Adjusts the span of the measured value. You can calibrate the
error occurred by slanting of the measurement target by using
this setting.
Item Default value Setting range
Baud rate [BAUDRATE] 9600 9600, 14400, 19200, 38400, 57600, 115200
Parity check [PARITY] NONE NONE, EVEN, ODD
Stop bit [STOPBIT] 1 1, 2
Data length [D-LENGTH] 8 7, 8
Data mode [D-MODE] OFF OFF, S0, S1, S2
Item Default value Setting range
Program selection CONSOLE CONSOLE, TERMINAL
method [P-SELECT]
Program copy P0 TO P0 Copied from: P0 to P7, EE (initialize)
[P-COPY] Copied to: P0 to P7
Initialization of all programs CANCEL CANCEL, YES
[P-CLEAR]