I/O Terminal
E LT-9001-IM
7-9
Timing Chart
The timing charts in the normal measurement and in the profile data output are as follows.
Normal/Auto peak hold/Auto bottom hold/Auto peak-to-peak hold
The minimum input time (T1), sampling cycle (T2), scanning change time (T3), RESET time (T4), and
update cycle (T5) vary according to the settings.
Refer to "Timing Details" (page 7-13) for details.
T3 is required only when the scanning setting is to be changed.
Stability output is always output in a sampling cycle (T2).
Peak hold/Bottom hold/peak-to-peak hold/average hold/sample hold
The minimum input time (T1), sampling cycle (T2), scanning change time (T3), and RESET time(T4) vary
according to the settings.
Refer to "Timing Details" (page 7-13) for details.
With RESET input, the internal measured value is fixed after the RESET time has elapsed.
T3 is required only when the scanning setting is to be changed.
STABILITY output is always output in a sampling cycle (T2).
Normal Measurement (When Profile Output is OFF)
MinT1