Owner manual
9-4
Specifications
■ Common to the displacement mode and the shape mode
Status Table
E LT-9001-IM
Specifications
9
Chapter
Screen Input Output RS-232C
Measured
Limits
Timing/Reset
Auto-zero
Program No. Judgment
Stability
Incoming Response
value display
display
change output output
Numerical
Measured
Judgment
Comparator
value
value display result
Over range at
Display range
HI HI
plus side
upper limit
Over range at
Display range
LO LO
minus side
lower limit
Dark --DARK--
Not available
All OFF
Judgment
--------
Not available
All OFF
standby
During RESET
--------
Not available
All OFF
processing
During setting
Not available Not available
Same as during
Returns
measurement
an error
Input error
Error display
Judgment
Same as during
OK
measurement
Other errors
Error display
Not available
All OFF OFF
Returns
an error
When power
Title screen All OFF OFF
Returns
is turned on an error
* OK/NG indicates a validity/invalidity of input.
During measurement
Normally
active
depending
on the
measurement
status
Pages
7-5 and
7-9
OK
OK
NG
NG NG
OK
NG
NG
OK
OK
■ When the profile output in the displacement mode and the profile mode is set to OFF
Output
Analog output
Binary output
Data output Strobe output
Numerical value
Over range at plus side +10.5V
+1048575
(0x0FFFFF
)
Over range at minus side -10.5V
-1048576
(0x100000)
Dark -10.5V
-1048576
(0x100000)
Judgment standby -10.5V
-1048576
(0x100000)
During RESET processing -10.5V
-1048576
(0x100000)
During setting Same as during measurement
Input error Same as during measurement
Other errors -10.5V 0 (0x000000) OFF
When power is turned on -10.5V 0 (0x000000) OFF
Output according to the
measured value of
OUT1/OUT2
OUT STB
* Only when I/O is
binary.
pages 7-10 and 7-13
Voltage according to the
measured value of
OUT1/OUT2
When it exceeds ±10 V,
+10.5 V at the plus side
-10.5 V at the minus side
During measurement
OK
OK