Instruction Manual
6-17
6-5 Setting Commands for the N-410 Series
Serial Communication
6
Protocol settings
Protocol settings (only available when using PLC link)
Function Command sent Response Explanation
Communication protocol
settings
* Use the next command for
handshake details
Change WP07n OK
n = 0: No handshake
1: PASS/RTRY
2: ACK/NAK
Confirm RP07 07n
Header settings
Change WP51hhh... OK hhh... = Header (Up to 5 characters)
*Settings are specified in hexadecimal
(up to 10 characters).
*If nothing is specified, hhh... = FF
Confirm RP51 51hhh...
Delimiter settings
Change WP52hhh... OK hhh... = Delimiter (Up to 5 characters)
*Settings are specified in hexadecimal
(up to 10 characters).
*If nothing is specified, hhh... = FF
Confirm RP52 52hhh...
ID number addition
Change WP09n OK
n = 0: Do not add anything
1: Add
Confirm RP09 09n
Add checksum
Change WP39n OK
n = 0: Do not add anything
1: Add
Confirm RP39 39n
Function Command sent Response Explanation
PLC link device
Change WP36n OK n = 0: No PLC link
1: SYSMAC Series
2: MELSEC Series
3: KV Series
Confirm RP36 36n
Trigger input via PLC link
Change WP37n OK
n = 0: Do not use
1: Use
Confirm RP37 37n
DM head address
Change WP40nn OK
nn = 00 to 99
(0000 to 9900)
Confirm RP40 40nn
PLC device / station number
Change WP43nn OK
nn = 00 to 31
Confirm RP43 43nn