Instruction Manual

1-6
N-410 Overview
1
1-3 Part Names
N-R4
States of RS-422A/485 changeover switch and terminating resistance switch
* Factory settings are by default RS-485 communication and the terminating resistance set to the
OFF position.
Number Name Function
1 Head port Used to connect the head.
2 Power LED Lights when the power is ON.
3
Communication status
LED
Monitors the status of communication with the head.
4 RS-422A/485 connector Used to connect to the host (personal computer, PLC).
5 I/O status LED Monitors the ON/OFF status of the I/O terminals.
6 I/O terminals Used to connect I/O signal lines of control units.
7 Power terminal Terminal for 24 V DC power supply input.
8 DIN rail mounting tab Used to secure the N-R4 to a DIN rail.
9
RS-422A/485
changeover switch
Used to switch between RS-422A and 485 communications.
10
Terminating resistance
switch
Used to switch between ON and OFF for terminating resistance.
1. Head port
2. Power LED
4. RS-422A/485 connector
5. I/O status LED
6. I/O terminals
7. Power terminal
8. DIN rail mounting tab
9. RS-422A/485
changeover switch
3. Communication status LED
10.Terminating
resistance switch
Number
RS-422A
communication mode
RS-485
communication mode
Terminating
resistance ON
1 Left Right -
2 Left Right -
3- - Right