Instruction Manual

Installation
2
2-5
2-2 N-410 Connections and Wiring
This section explains how to connect the N-410 to other devices.
Installing and Wiring the Input and Output Jacks
* These appear in this order from left to right on the terminal.
A bar terminal (I terminal) like that shown in the figure can be used.
Electrical wiring
Connect the N-410 to a 24 V DC power supply.
Connect the 24 V DC power source to the "IN" side of the power terminal to use the "OUT" side of
the terminal as a 24 V DC power supply (However, be certain that the power supply coming into
the "IN" side is will have enough power to power the device connected to the "OUT side").
Symbol Explanation Signal direction
TIM Trigger input Input
COM Trigger input common Input
RS-485 SG RS-485 ground signal -
RS-485 + RS-485 + side Input/output
RS-485 - RS-485 - side Input/output
DC OUT
24 V DC power source output + side Output
24 V DC power source output - side Output
DC IN
24 V DC power source input + side Input
24 V DC power source input - side Input
RS-485
TIM COM
SG 24V 0V 24V 0V
DC OUT DC IN
5 mm max.
6 mm min.
2.0 mm
max.
Recommended manufacturer:
Maker: JST Manufacturing Company, Ltd.
Model: VTUB-1.25
DC OUT DC IN
24V DC
+
24V 0V 24V 0V
Use an NEC class 2 output
power source for UL
certification.