Instruction Manual
2-20
Installation
2
2-5 N-48 Connections and Wiring
Connecting to a BL/SR/RF Series Device
Connect a BL-700/600/180 Series or 210RK device to the reader board of the N-48.
When connecting a BL-1300 Series/SR Series/RF Series device to the N-48, use a option D-sub
converter cable (RF-CM2D).
* The baud rate of a code reader connected to the N-48 should be 38400 bps or less.
Pin Layout
N-48
BL series
READER
POWER
TERMINATOR
ON
SD RD
N-48
N-410
Computer
RS-232C cable
(OP-29860)
RS-485
twist pair cable
D-sub converter cable
(RF-CM2D)
(BL-1300, SR:OP-80616)
Pin number Symbol Function
Signal
direction
1 TIM Trigger input Output
2 RD (RXD) Send data Output
3 SD (TXD) Receive data Input
4 OK OK Input
5 GND (SG) Ground (Common ground for all signals) -
6 NG NG Input
7 RS (RTS) Send capability Input
8 CS (CTS) Request send Output
9 +5V 5 V power source output (600mA) Output
6789
12345
D-sub9 pin (male)
DCE specification
(modem definition)
#4-40 screws