Instruction Manual

5-3
5-1 Multi-head Mode
Controlling Multi-head Mode
5
Settings
Refer to "2-1 Making Settings and Connections" (Page 2-2) for the procedure for making
settings and connections.
The section explains how to make the settings for the N-410, BL/SR/RF Series devices, the NX-
50RS and the computer.
Settings for BL/SR/RF Series devices
When using an N-R4, N-48 and BL-U1
1. Set multi-drop link to "Enabled".
2. Set the ID number of the BL/SR/RF Series device to be connected to a number from 1 to
31.Make sure that no ID numbers are duplicated.
3. Change the settings for baud rate, data bits and stop bit length to match the RS-485 side of the N-410
settings. The factory default settings are as follows.
4. The communication protocol disables the RTS/CTS protocol, even if it is set.
5. Set the header to "None". Terminator settings are disabled.
*Change other settings as necessary.
When using an NX-50RS
1. When using an NX-50RS as a power supply, the settings above are unnecessary.
Connect the BL/SR/RF Series device to the NX-50RS as is.
2. Use the AutoID Navigator to set the ID numbers on the NX-50RS device to a number from 1 to
31. Make sure that no ID numbers are duplicated.
3. Change the settings for baud rate, data bits and stop bit length to match the RS-485 side of the N-410
settings. The factory default settings are as follows.
* For more information on using AutoID Navigator and on NX-50RS settings, refer to the
"AutoID Navigator User's Manual"
Do not change the factory-configured status of the following items. The default settings are
in parentheses.
Read mode (Single read mode)
Data transmission timing (after read)
Read error code (ERROR)
Model BL Series SR Series RF Series N-410
Baud rate 9600 bit/s 115200 bit/s 9600 bit/s 115200 bit/s
Data bits 7 bit 8 bit 8 bit 8 bit
Parity Even Even None Even
Stop bit length 1 bit 1 bit 1 bit 1 bit
Model NX-50RS
Baud rate 115200 bit/s
Data bits 8 bit
Parity Even
Stop bit length 1 bit
Note