96M10106 High-speed, High-precision Free-layout Static Elimination Blower 300 Series Instruction Manual Before using this Free-layout Elimination Blower, be sure to thoroughly read this Instruction Manual. After you are finished with this Instruction Manual, be sure to store it in a safe place for quick reference.
Preface This document describes handling, method of operation and precautions when using the High-speed, High-precision Free-layout Elimination Blower Unit SJ-F300 Series. Before you start to use the SJF300 Series, be sure to thoroughly read this document in order to make full use and safely use the functions of the SJ-F300 Series. Store this document in a safe place so that you can retrieve it whenever necessary.
1-2 Checking the Contents of the Package Precautions on Regulations and Standards ■ CE Marking The package contains the following components and accessories. Before getting started, make sure that the package contains everything that it is supposed to contain. Keyence Corporation has confirmed that this product complies with the essential requirements of the applicable EC Directive, based on the following specifications.
1-3 Names and Functions of Parts 1-3 Names and Functions of Parts Static Elimination Blower Unit Static elimination blower unit operation panel Controller Unit (I/O Terminal Section) Lock switch IONLEVEL Electrode Unit COND START /STOP BALANCE ION FAN Fan guard [1] Electrode needle [2] [3] [4] [5] [6] [7] [1] Ground terminal ..... Be sure to connect a Class D earth. [2] DC power terminal ..... 24 VDC ±10% [3] 0 V terminal .....
2-1 Before Installation 2-2 Connection and Installation 2CONNECTION AND INSTALLATION Before you install this product, examine carefully the distance between the Static Elimination Blower Unit and the target object and the time required for static elimination. Installing the SJ-F300 Series About Static Elimination Performance Install the SJ-F300 Series at locations where static electricity is generated or is likely to be generated.
2-2 Connection and Installation 2-2 Connection and Installation ■ Installing an additional Static Elimination Blower Unit Connect the output terminal [OUT] of the Static Elimination Blower Unit with the input terminal [IN] of a Static Elimination Blower Unit to add using a blower-blower extension cable. Connecting Cables When you have finished with installation, connect the earth lead, the connection cable for the Static Elimination Blower Unit and the power supply.
3-1 Flow of Operation 3-3 Operation 3FUNCTION AND OPERATION The following chart shows the operational flow from installing the SJ-F300 Series, connecting cables to starting/stopping static elimination of the target object. Conduct connection and installation Operation of Power Supply This section describes how to operate the power supply of the Controller Unit and the Static Elimination Blower Unit.
3-3 Operation 3-3 Operation ■ Blow rate adjustment using the Static Elimination Blower Unit This allows individual blow rate adjustment of each Static Elimination Blower Unit. 1 2 3 Press or to select the blow rate indicator. The blow rate indicator lights in red. Adjusting Ion Balance Blow rate indicator The SJ-F300 Series senses the charged amount of the target object by the I.C.C. function to automatically control the emission (balance) of plus and minus ions.
3-3 Operation 3-4 About Display Function ■ Displaying blow rate setting value monitor Press or to select the blow rate indicator to display the blow rate setting value monitor. The LED lit closer to the + side indicates higher blow rate; and the LED lit closer to the - side indicates lower blow rate. Turning Off Static Elimination Static elimination can be turned off using the Controller Unit or the Static Elimination Blower Unit in a powered ON state.
4-1 About Maintenance 3-4 About Display Function ■ Condition alarm output function 4MAINTENANCE Maintenance must be performed periodically to ensure that the static elimination performance of the SJ-F300 Series is fully demonstrated. For maintenance, be sure to thoroughly read the descriptions under "Safety Precautions" ( page 1), and pay attention to the following points. This function causes the condition alarm output indicator to blink and an alarm signal (control output [N.O.
5-1 Timing Charts 4-2 Performing Maintenance on the Electrode Needles 3 Install the Electrode Unit. Make sure that the lock switch on the Static Elimination Blower Unit is unlocked, and then insert the Electrode Unit. Make sure that the Electrode Unit is slowly inserted all the way, and then lock the lock switch to fasten the Electrode Unit in place.
5-2 Specifications 5-3 External Dimensions ■ Controller Unit/Static Elimination Blower Unit Static Elimination Blower Unit Controller Unit SJ-F030 (Wide type) ±7000 V max. Applied voltage ±10 V ±5 V 3.5 m/s 0.8 m/s 0.005 ppm max. Static elimination stop input NPN open collector or no-voltage contact signal Alarm output 120 (Fixing part 121) SJ-F030 61.5 SJ-F035 66.5 5.5 24 VDC±10% Current consumption Weight (50) 100 mA (40 V max.
1 Troubleshooting AAPPENDICES 2 Table of Indicated States ■ Indicated states during setting change, confirmation and operation (excluding when the power is turned ON) This appendix describes troubles that may occur during the use of this product and troubleshooting methods. Check the following table before sending in your SJ-F300 Series for repair.
2 Table of Indicated States WARRANTIES AND DISCLAIMERS Lit State Description Ion level alarm indicator blinks in red. (1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples.