Instruction Manual

21
E SK-1000 IM
Display Screen and Output
Normally, the judgment value (P.V.) is displayed on the main display (upper level).
This section describes the judgment output and analog output status when
displays other than numbers appear on the main display.
Reference
The judgment indicator on the sensor amplifier operates in the same
way as Normally Open regardless of the output state setting.
Status
Amplifier Control input Control output
Analog
output
Upper
level
main
display
Judgment
indicator
Timing/
Reset
Bank
switching/
emission
stop
Zero-shift
Judgment
output
Alarm
Vol tage
(current)
value
Measuring
Judgment
value
(P.V)
Measure-
ment
results
Yes Yes Yes
Measure-
ment
results
Output:
ON
Display:
OFF
Voltage
(current) for
measured
value
Out of
measurement
range
----- All off Yes Yes No All OFF
Output:
OFF
Display:
ON
Analog
voltage
output: 5.5 V
fixed
Analog current
output: 3.0 mA
fixed
Out of display
range
FFFF
Only HI
lights
Yes Yes No
Only HI
output ON
Output:
ON
Display:
OFF
Upper limit of
analog output
range (For 1-5
V, fixed to 5 V)
(When upper
limit < lower
limit: 1 V)
Out of display
range
-FFFF
Only LO
lights
Yes Yes No
Only LO
output ON
Output:
ON
Display:
OFF
Lower limit of
analog output
range (For 1-5
V, fixed to 1 V)
(When upper
limit < lower
limit: 5 V)
Setting
Setting
item
Follows
setting
details
During
error:
No
Other
than
error:
Yes
Yes
Outside
measure-
ment
range,
during
error: No
Follows
setting
details
Output:
ON
Display:
OFF
Follows
setting details
Other than [Erc],
[ErE] errors
" Error
Displays and
Corrective
Actions" (page
20)
Error
display
HI/LO
simulta-
neously
light
No Yes No
HI/LO
output
simultane-
ously ON
Output:
OFF
Display:
ON
Analog
voltage
output: 5.5 V
fixed
Analog current
output: 3.0 mA
fixed
Overcurrent error
ErC All off Yes Yes Yes All OFF
Measure-
ment in
progress,
or same as
out of mea-
surement
range
Voltage
(current) for
measured
value
EEPROM error
ErE
Measure-
ment
results
Yes Yes Yes
Measure-
ment
results
Measure-
ment in
progress,
or same as
out of mea-
surement
range
Voltage
(current) for
measured
value
-----
FFFF
-FFFF
ErC
ErE
Factory Setting (Default Value) List
This section describes the factory settings (default values).
If the initial reset is performed, the following default values will be restored.
" Initial Reset (Initialize)" (page 8)
Values set on the main screen
Banks 0 to 3 will all be set to the same values.
Basic settings and advanced settings
Setting item Default value
HI tolerance setting value 1.000
LO tolerance setting value -1.000
Setting item
Default
value
Description
1. Measurement range
near
Measurement can be performed in the range of 0
to ±2 kV and the reference distance for
measurement is 25 mm.
2. Averaging rate
64
Averaging rate: 64
3. Output state
no
Normally open
4. Distance setting
dEFLt
The distance will not be corrected.
5. Area scaling
1.00
1.00
6. Hold function
S-H
Sample hold.
7. Timing input
LEvEL
Level
8. Hysteresis
0.100
0.100
9. Analog output scaling
dEFLt
Default setting
10. External input
dEFLt
Default setting
11. Bank switching method
btn
Button operation
12. Zero shift value memory
function
M-oFF
Data will not be stored in the nonvolatile memory
(EEPROM).
13. Display digit
dEFLt
Default setting