Owner manual

Chapter 2 Installation and Assembly
2-13
2
ENGLISH
3. Tighten the bolt with the hexagon socket enough to hold them in place.
4. Tighten the bolts with the hexagon sockets with a mounting torque of 7 N•m while holding the
beveled area at the end of the bar (10 mm (0.39") diagonally) in place with a wrench.
5. Then use M3 (L=7) screws to attach the bar brackets to the SL-CHG unit. Make sure the bar is not
skewed.
6. Use M3 (L=7) screws with standard mounting brackets A, B, and C, as well as with L-shaped
mounting brackets. Install 1 intermediate support bracket (included) onto protection bars used with
36 or more beam axes. For information about how to install the intermediate support bracket, see
"2-8 E-to-E mounting bracket assembly and installation". For information about the position at which
the bracket should be installed,
see “1-4 Dimensional Drawings (Dimensions by model) (page 1-
7)”.
5
3
4
[Bottom]
[TOP]
*The bar should be secured
to the bottom in the same way.
Recommended tightening torque:
0.7 N•m
Recommended tightening torque:
7 N•m
* Non standard mounting bracket present or L-shaped mounting bracket: screw length is M3 (r=7).
Standard mounting bracket present or L-shaped mounting bracket: screw length is M3 (r=10).
Number of required protection bar intermediate support brackets and E-to-E mounting brackets
Model
Compatible
No. of Bar support brackets
Intermediate
Model
support bracket
OP-42350 SL-C08HG None None
OP-42351 SL-C12HG None None
OP-42352 SL-C16HG None None
OP-42353 SL-C20HG None None
OP-42354 SL-C24HG None None
OP-42355 SL-C28HG 2 None
OP-42356 SL-C32HG 2 None
OP-42357 SL-C36HG 21
OP-42358 SL-C40HG 21
OP-42359 SL-C44HG 21
OP-42360 SL-C48HG 21
OP-42361 SL-C52HG 21
OP-42362 SL-C56HG 21
OP-42363 SL-C60HG 21
OP-42364 SL-C64HG 21
WARNING
When mounting the SL-CHG to a machine, use the mounting method shown in this
instruction manual, and make sure the SL-CHG is securely mounted.
Insufficiently tightened screws or incorrect mounting of the SL-CHG may cause a
serious accident, such as serious injury or death of the machine operator.
When mounting the models SL-C32HG to SL-C64HG, be sure to use the
intermediate support bracket provided with the accessories and mount it in the
correct location for the SL-CHG Series.