(1) The SL-V is not muted when the mold is at or stays at the bottom dead cen-
ter of press cycle. At this point, the SL-V continues normal operations, and
OSSD goes OF if the SL-V gets interrupted.
(2) When switch A1 turns ON first, and then switch A2 turns ON. Then the SL-V
goes into the muted condition and the OSSD does not turn OFF even if the
SL-V detects an interruption.
(3) The SL-V continues the muted condition because both switches stay turned
ON and the mold continues to stay at the top dead center position.
(4) The SL-V will go back to normal operation (not muted) as soon as sensor A1
turns OFF after the mold starts downward.
(5) The SL-V continues normal operation while the mold is going downward.