Owner's manual
4-4 Examples of Wiring
4-7
Wiring
4
SL-V-M-NO4-E
Automatic reset mode
When not using the EDM function
Manual reset mode
K1, K2 : External device (Safety relay unit, etc.)
K3 : Solid state contactor
*1
S1 : The switch for wait input (N.O.)
*1
The violet wire needs to be capped it is not used.
(Open circuit : completely disconnected)
S2 : The switch for releasing lockout condition (N.C.)
The yellow wire must be short-circuited to 0 V if this
function is not used.
M : 3-phase motor
PLC : For the monitoring use
*1
*1 These are NON SAFETY-RELATED system.
K3
K2K1
M
IN
OUT
PLC
S1
S2
Cable insulation: Black
Cable insulation: Grey
Transmitter
Receiver
(Interlock-reset-ready output) Green
(+24 V) Brown
(+24 V) Brown
(OSSD2) White
(OSSD1) Black
(Reset input) Yellow
(EDM input) Red
(Wait input) Violet
(AUX output) Red
(0 V) Blue
(0 V) Blue
Shield
Shield
K2
K1
(Interlock mode selection input) Pink
Orange/black
(Communication cable 2)
Orange
(Communication cable 1)
S1
S2
K1
K2
K3
K2K1
M
IN
OUT
PLC
Cable insulation: Black
Cable insulation: Grey
Transmitter
Receiver
(Interlock-reset-ready output) Green
(+24 V) Brown
(+24 V) Brown
(OSSD2) White
(OSSD1) Black
(Reset input) Yellow
(EDM input) Red
(Wait input) Violet
(AUX output) Red
(0 V) Blue
(0 V) Blue
Shield
Shield
K2
K1
(Interlock mode selection input) Pink
Orange/black
(Communication cable 2)
Orange
(Communication cable 1)
K1, K2 : External device (Safety relay, magnet contactor,
etc.)
K3 : Solid state contactor
*1
S1 : The switch for wait input (N.O.)
*1
The violet wire needs to be capped it is not used.
(Open circuit : completely disconnected)
S2 : The switch for reset input (N.O.)
M : 3-phase motor
PLC : For the monitoring use
*1
*1 These are NON SAFETY-RELATED system.