Owner's manual

4-4 Examples of Wiring
4-8
Wiring
4
SL-V-M-NO4-E
When using a multi-function type cable (PNP output type cable)
Manual reset mode
The shielding wire of the PNP output type cable is connected to 0 V line in the SL-V.
Do not connect the shielding wire to +24 V line.
When using a multi-function type cable (NPN output type cable)
Manual reset mode
The shielding wire of the NPN output type cable is connected to +24 V line in the SL-V.
Do not connect the shielding wire to 0 V line.
K1, K2 : External device (Safety relay
unit, magnet contactor, etc.)
K3 : Solid state contactor
*1
S1 :
The switch for wait input (N.O.)
*1
The violet wire needs to be
capped it is not used. (Open
circuit : completely
disconnected)
S2 : The switch for reset input (N.O.)
S3 : The switch for override input
(N.O.)
L1 : Muting lamp (Incandescent
lamp or LED lamp)
P1, P2 : Muting device (PZ self-
contained photoelectric sensors
<PNP output>, etc.)
M : 3-phase motor
PLC : For the monitoring use
*1
*1
These are NON SAFETY-RELATED system.
S1
S2
S3
K1
K2
K2
K3
K2K1
M
IN
PLC
OUT
K1
L1
P 1
P 2
(Interlock mode selection input) Pink
Cable insulation: Black
Cable insulation: Grey
Transmitter
Receiver
(Interlock-reset-ready output) Green
(+24 V) Brown
(+24 V) Brown
(OSSD2) White
(OSSD1) Black
(Reset input) Yellow
(EDM input) Red
(Override input) Red/black
(Muting lamp output) Yellow/black
(Muting input 1) Light blue
(Muting input 2) Light blue/black
(Wait input) Violet
(AUX output) Red
(State information output 1) Grey
(State information output 2) Grey/black
(Alert output) Pink/black
(Clear/Blocked output) White/black
(0 V) Blue
(0 V) Blue
Shield
Shield
Orange/black
(Communication cable 2)
Orange
(Communication cable 1)
Brown
Brown
Blue
Blue
Black
Black
Caution
K1, K2 : External device (Safety relay
unit, magnet contactor, etc.)
K3 : Solid state contactor
*1
S1 :
The switch for wait input (N.O.)
*1
The violet wire needs to be
capped it is not used. (Open
circuit : completely
disconnected)
S2 : The switch for reset input (N.O.)
S3 : The switch for override input
(N.O.)
L1 : Muting lamp (Incandescent
lamp or LED lamp)
P1, P2 : Muting device (PZ self-
contained photoelectric sensors
<NPN output>, etc.)
M : 3-phase motor
PLC : For the monitoring use
*1
*1
These are NON SAFETY-RELATED system.
S1
S2
S3
K1
K2
K2 K1
L1
P 1
P 2
K3
K2K1
M
IN
PLC
OUT
Cable insulation: Black
Cable insulation: Grey
Transmitter
Receiver
(Interlock-reset-ready output) Green
(Interlock mode selection input) Pink
(+24 V) Brown
(+24 V) Brown
(OSSD2) White
(OSSD1) Black
(Reset input) Yellow
(EDM input) Red
(Override input) Red/black
(Muting lamp output) Yellow/black
(Muting input 1) Light blue
(Muting input 2) Light blue/black
(Wait input) Violet
(AUX output) Red
(State information output 1) Grey
(State information output 2) Grey/black
(Alert output) Pink/black
(Clear/Blocked output) White/black
(0 V) Blue
(0 V) Blue
Shield
Shield
Brown
Brown
Blue
Blue
Black
Black
Orange/black
(Communication cable 2)
Orange
(Communication cable 1)
Caution