Owner's manual
2-11 Temporary Suspension of Safety Function
2-32
Functions and Features
2
SL-V-M-NO2-E
Muting bank function
The muting bank function can be activated through the SL-VH1S.
You can configure the muting bank, which is a group of the beam axes that will become muted condition
in case of activation of muting. SL-V can have three of muting banks. In order to select the muting bank
to be activated, you have to switch (ON and OFF) the muting bank input.
If multiple muting bank inputs are ON at the same time, only the beam axes set to be muted on all active
muting banks will be muted.
Example) Using the muting bank function with the SL-V08H
(M: Muted; : Normal)
System Limitations for the Muting Bank Function
• Wait input and the override function cannot be used.
• The interlock cannot be set through the wiring. (This can be set through the SL-VH1S. Refer to the
"SL-VH1S User’s Manual" for more details.)
Wiring for the Muting Bank Function
Time Chart for the Muting Bank Function
Muting bank input 1
(Violet line)
Muting bank input 2
(Red/black line)
Muting bank input 3
(Pink line)
Muting bank 1 active ON OFF OFF
Muting bank 2 active OFF ON OFF
Muting bank 3 active OFF OFF ON
Setting and state Beam 1 Beam 2 Beam 3 Beam 4 Beam 5 Beam 6 Beam 7 Beam 8
Muting bank 1 setting MMMM
Muting bank 2 setting MMMM
Muting bank 3 setting M M M M M M M M
Muting banks 1 & 2 active MM
Muting banks 1 & 3 active MMMM
Muting banks 2 & 3 active MMMM
Muting banks 1, 2 & 3 active MM
No muting banks active
Reference
Brown
Blue
Muting bank input 1 (violet)
Muting bank input 2 (red/black)
Muting bank input 3 (pink)
Short-circuit current: 2.5mA
Transmitter
or
receiver
Main
circuit
0 V
+24 V
Brown
Blue
Muting bank input 1 (violet)
Muting bank input 2 (red/black)
Muting bank input 3 (pink)
Short-circuit current: 2.5mA
Transmitter
or
receiver
Main
circuit
0 V
+24 V
When using a PNP output type cable When using an NPN output type cable
Muting bank input 1
Muting bank input 2
Muting bank input 3
Muting banks inactive Muting banks inactive
Active banks
ON
OFF
ON
OFF
ON
OFF
200 ms or less
1 1&2
1
&
2
&
3
1&3 1
200 ms or less 200 ms or less 200 ms or less 200 ms or less 200 ms or less