96008E Safety Light Curtain SL-V Ver.3 Configuration Software (SL-VH1S) SL-V Configurator User's Manual Read this manual and the SL-V user's manual before using the product in order to understand the features. Always keep this manual in a safe place for future reference.
Introduction This user's manual describes functions and handling of the SL-VH1S , the dedicated software for the SL-V Ver.3. Read this user's manual thoroughly before operating in order to understand the software features, and keep this user's manual readily available for reference. Ensure that the end user of this product receives this manual. Before using , make sure to read the "Safety Light Curtain SL-V Series Ver.
Terms of License Agreement on Use of the Software Software License Agreement The use of [SL-VH1S ] (hereinafter referred to as [this software]) is subject to the terms outlined in this software license agreement (hereinafter referred to as [this agreement]) and to the customers consent to this agreement. The customer's use or duplication of this software, in whole or in part, constitutes the customer's consent to enter into this agreement.
Table of Contents Introduction Terms of License Agreement on Use of the Software............................................................. 1 Table of Contents .................................................................................................................... 2 Chapter 1 Before Use 1-1 Checking Package Contents ...................................................................................... 1-2 1-2 Using the Configurator ........................................................
Table of Contents Chapter 3 3-1 Configuration of Each Function Safety Related Configuration ..................................................................................... 3-2 Muting Configuration .................................................................................................................... 3-2 Override Function ......................................................................................................................... 3-2 Interlock Configuration...................
Table of Contents MEMO 4 SL-VH1S-NO0-E
1 Before Use SL-VH1S-NO1-E 1-1 Checking Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 1-2 Using the Configurator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1-3 System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 1-4 Installing the . . . . . . . . . . . . . . . . . . . . . 1-5 1-5 Connecting the SL-V and the Computer . . . . . . . . . . . . . . . . .
1-1 1 Checking Package Contents The following items should be found in the package. Make sure that each of these items is present. Before Use Installation CD-ROM x1 This disc contains the installer. Keep this disk in a safe place after installation. Note 1-2 It is recommended that the CD-ROM be backed up in case of damage to or loss of the disk.
1-2 Using the Configurator 1 The allows various configurations on the SL-V Series version 3 to be configured Before Use from the PC. Create/Save configurations Upload configurations Computer Read configurations Monitor light intensity SL-V Series Ver.3 • Settings can be configured even when the computer is not connected to the SL-V. • The receiver on the main unit is needed to configure and upload configuration.
1-3 1 System Requirements The system requirements for the are as follows. Before Use CPU Pentium III 1.2 GHz or greater Compatible OS*1 Windows XP (SP3 and later versions) Windows Vista (SP1 and later versions) Windows 7 Memory capacity 512 MB or greater Hard disk space 30 MB or greater CD-ROM drive Required Communication interface USB 1.1/2.0 Display XGA (1024 x 768) or greater, 256 colors or greater (High Color or greater recommended) Operating environment .
1-4 Installing the 1 This section explains how to install the on your computer. Before Use Preparation Confirm the following before installing the software. Note It is recommended that the CD-ROM be backed up in case of damage to or loss of the disk. Hard disk space The must be installed to a hard disk. The hard drive for installation must have at least 30 MB (330 MB if .NET Framework2.0 is not installed) of free space.
1-4 Installing the 1 Installation Before Use This section explains how to install the software, using the following drive setup. C drive: Hard disk drive E drive: CD-ROM drive Start Windows and insert the "SL-V Configurator Installer CD-ROM" into the CD-ROM drive. • The install program will be started by the computer’s auto run function. If the install program does not start, select "Run...
1-5 Connecting the SL-V and the Computer 1 This section explains how to connect the SL-V Configurator and the computer. • The interface unit SL-V1UB and USB 1.1-compatible USB cable (Supplied with the SL-V1UB) and the SL-V connection cable are required to connect the SL-V to a computer. • Only one interface unit can be connected to each computer. 1-to-many and many-to-1 connections are not possible. • All settings can be configured with SL-V Ver.2/Ver.1 in a serial connection as subunits.
1-5 Connecting the SL-V and the Computer 1 Connecting Before Use This section explains how to connect the SL-V and the computer. Note • Turn on the power after all of the connections are completed. • Turn off the power before removing any of the connectors. • When the SL-V is positively grounded using the SL-V connection cable for the NPN output type, do not ground on the computer side. (Communication cannot be established if grounded.
1-5 Connecting the SL-V and the Computer 4 1 Turn on power. Blue Refer to the "SL-V Series Ver. 3 Safety Light Curtain Instruction Manual" or the "SL-V Series Ver. 3 Safety Light Curtain User’s Manual" for more information on wiring. 24V SL-V connection cable (receiver) Reference To monitor light intensity, connect SL-V connection cable (transmitter) to the SL-V device transmitter. Turn on the power and connect the communication line to the transmitter.
1-5 Connecting the SL-V and the Computer 1 MEMO Before Use 1-10 SL-VH1S-NO1-E
2 Basic Operation SL-VH1S-NO2-E 2-1 Names of Parts in Main Window . . . . . . . . . . . . . . . . . . . . . . . 2-2 2-2 Flow of Basic Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 2-3 Startup and Exiting the . . . . . . . . . . . . . 2-5 2-4 Configuring the Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 2-5 Setup of the Password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 2-6 Login/Logout . . . . . . . . .
2-1 Names of Parts in Main Window This section describes the names of parts in main window and outline of its functions. 2 Menu Bar Basic Operation Toolbar Configuration Tab Function Configuration Area Status Bar Menu Bar This displays the menu to execute each function. For list of operation menu, refer to "A-2 Operation Menu List" (Page A-3). Toolbar Buttons for frequently used function is here. Icon Description This will configure the model configuration.
2-1 Names of Parts in Main Window Configuration Tab 2 Item that can be configured in the function configuration area is switched by clicking on the Basic Operation Configuration tab. Item Description Safety Related Configuration This will configure the safety related configurations, such as muting or interlock.
2-2 Flow of Basic Operation This section describes the basic flow of operation of the . 2 Note Basic Operation Have the installed on the PC before proceeding. "1-4 Installing the " (Page 1-5) Creating the Configuration on the PC Configuration is created on the PC. Configuration can be created on the PC while it is not connected to the SL-V. Start up the . Select the startup method. Configure the functions.
2-3 Startup and Exiting the This section describes the method of startup/exiting the . 2 Startup of the Basic Operation is started in following method. Note 1 cannot be started up twice. Double-click the [SL-V Configurator] shortcut icon on the desktop. If there is not icon on the desktop, select Start menu [All Programs (or Programs)] [Keyence Applications] [SL-V Configurator].
2-3 Startup and Exiting the When "Create New Configuration" is selected When "Create New Configuration" is selected, the [System Information] dialog is displayed. 2 The will startup with initial configuration by entering the information of the model to Basic Operation create the configuration, and clicking on [OK]. (1) (4) (2) (3) (5) (6) (7) (8) Item Description (1) Main Unit Type (No need to select.
2-3 Startup and Exiting the To read the existing configuration file When "Open the Configuration file" is selected, the [Open] dialog is displayed. Configuration file will open by selecting the file (*.sld), and clicking on the [Open] Basic Operation button. Reference To open the file later, select [File] [Open] from the menu. Exiting the To exit the , select [File] [Exit] from the menu.
2-4 Configuring the Functions Configure the functions from the Main window. For contents about configuration items, refer to "Chapter 3 Configuration of Each Function" (Page 3-1). 2 Configuration Tab Basic Operation Items will switch by clicking on the Configuration tab.
2-5 Setup of the Password Initial configuration of the SL-V password is necessary before uploading to the SL-V for the first time. Important 1 • Initial configuration of the password is only possible when the SL-V is connected. • Initial configuration of the password is not possible if the password is already configured on the SL-V or the . • To change the configured password, refer to "4-6 Changing the Password" (Page 4-8). Select [Authorization] [Init Password] from the menu.
2-6 Login/Logout It is necessary to connect the SL-V and login to upload the configuration to the SL-V. 2 Note Basic Operation • Login is only possible when the SL-V is connected. "Connecting" (Page 1-8) • Perform the initial configuration of the password before attempting to login. "2-5 Setup of the Password" (Page 2-9) Logging In 1 Press the [Log-In] button in the Toolbar. The [Password is required] dialog is displayed. 2 Enter the password and press the [Log-In] button.
2-7 Uploading the Configuration to the SL-V The configuration created with the can be applied to the SL-V by uploading it. 2 Note 1 Always upload the configuration again whenever the main unit is replaced. • When the model configuration of the sub unit is changed after uploading the configuration, SL-V may not startup (lock-out) depending on the configuration. In this case, reconfigure the model configuration, and upload it again. • Uploading is possible only when logged in.
2-7 Uploading the Configuration to the SL-V 3 Click the [Next] button. Second page of the [Upload] dialog is displayed. 2 Basic Operation Important 4 Be sure to check the settings to be uploaded before clicking the [Accept] button. When unexpected settings are displayed, click the [Not Accept] button. When the [Not Accept] button is clicked, configurations are not set on the SL-V and the SL-V will not be started (It will go to lockout condition). To restore the SL-V, upload must be completed once.
2-8 Saving and Using the Configuration on the PC Created contents of configuration can be saved on the PC as needed. Saved configuration can be read later. 2 Saving the Configuration Basic Operation 1 Select [File] [Save As] from the menu. The [Save As] dialog is displayed. 2 Enter a file name, and click the [Save] button. Configuration file will be saved at the location specified in the [Save in]. Opening an Existing Configuration 1 Select [File] [Open] from the menu.
2-8 Saving and Using the Configuration on the PC MEMO 2 Basic Operation 2-14 SL-VH1S-NO2-E
3 Configuration of Each Function SL-VH1S-NO3-E 3-1 Safety Related Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 3-2 Non Safety Related Configuration . . . . . . . . . . . . . . . . . . . . . . 3-4 3-3 Blanking Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6 3-4 Muting Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1 Safety Related Configuration Configuration for safety functions, such as muting or interlock, is possible by clicking on the [Safetyrelated Configuration]. 3 Configuration of Each Function Muting Configuration Item Contents of Configuration Description Time between muting inputs* 1 sec / 3 sec (Default) / 10 sec / 30 sec / Not specified This will configure the input time period specification between the muting inputs 1 and 2. (The lower limit time of 0.04 sec cannot be changed.
3-1 Safety Related Configuration Interlock Configuration Contents of Configuration Item (When PC configuration is selected) Start Interlock Restart Interlock Note 3 By wiring (Default) Configuration is switched with the wiring. By PC Software Configuration is switched with the . Manual start (Default) OSSD will be set to OFF when the power is turned on. The device will start up with reset input. Automatic start Starts the device automatically when the power is turned on.
3-2 Non Safety Related Configuration By clicking on the [Non Safety-related Configuration] tab, the configuration for the functions useful to control, such as state information output or how the indicator is turned on can be configured. 3 Configuration of Each Function Emitting Frequency Contents of Configuration Item Emitting Frequency TYPE-A (Default) / TYPE-B Description Mutual interference is reduced by changing the transmitter frequency.
3-2 Non Safety Related Configuration Center Indicator Contents of Configuration Item (When StateIndicator Mode is selected)* Note 3 Normal (Default) Normal operation is performed. Built-In Indicator mode ON/OFF of the center indicator will be controlled by external input. OFF Center indicator will be constantly turned OFF. State Indicator Mode* Lighting of the center indicator can be selected depending on the state of the SL-V.
3-3 Blanking Area Configuration of blanking area is possible by clicking on the [Blanking Area] tab. 3 Configuration of Each Function (1) (5) (2) (3) (4) (6) Item (1) Description Capture*1 Amount of receiving light for the connected SL-V can be confirmed. (2) Reduced resolution setting This can select if the reduced resolution is to be used or not. *2 (3) Number of reduced resolution beam axes setting This will configure the number of ignored beams.
3-4 Muting Area Configuration of muting area is possible by clicking on the [Muting Area] tab. 3 Configuration of Each Function (1) (4) (2) (3) Item (5) Description (1) Capture* Amount of receiving light for connected light curtain can be confirmed. (2) Muting Bank Configuration This will configure if the muting bank function is to be enabled or not. (3) Unit Selection It is possible to switch the configuration target (main unit / sub unit 1 / sub unit 2) if it is connected in series.
3-4 Muting Area Note 3 Configuration of Each Function 3-8 • Muting bank function cannot be used if the configuration of switching of interlock is configured to Wiring. • Muting bank function cannot be used if the configuration of center indicator is configured as Built-in Indicator Mode.
4 Other Functions SL-VH1S-NO4-E 4-1 Creating New Settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 4-2 Changing the Type Configuration . . . . . . . . . . . . . . . . . . . . . . 4-3 4-3 Loading Configurations from the SL-V . . . . . . . . . . . . . . . . . . 4-5 4-4 Verifying the Configuration between PC and SL-V . . . . . . . . . 4-6 4-5 Monitoring the Received Light Intensity on the SL-V. . . . . . . . 4-7 4-6 Changing the Password . . . . . . . . . . . . . . . . . .
4-1 Creating New Settings New settings can be created. 1 Select [New] from the [File] menu. When the settings have been changed, the save confirmation dialog box appears. 4 NOTE Other Functions When you want to save the settings, click [Yes] to save the configuration file. When the [No] button is clicked, settings will be cleared without saving. The [System Information] dialog box appears. For the subsequent procedures, refer to 4-2 "When "Create New Configuration" is selected" (Page 2-6).
4-2 Changing the Type Configuration The type and the number of connected SL-V can be changed when creating the settings. NOTE 4 Other Functions 1 When the type configuration is changed, the following setting items will be initialized. • Reduced resolution • Area settings for fix blanking • Muting bank • Area settings for muting Click the [System] button of the toolbar. The [System Information] dialog box appears.
4-2 Changing the Type Configuration 2 Click the [OK] button. The [Warning] dialog box appears. 4 Other Functions 3 Click the [OK] button. The type configuration is changed, and the screen returns to the main screen.
4-3 Loading Configurations from the SL-V Settings can be loaded from the connected SL-V. NOTE When the [Download] button on the tool bar is clicked, settings are loaded from the connected SL-V. When the settings have been changed, the save confirmation dialog box appears. NOTE SL-VH1S-NO4-E If you want to save the settings, click [Yes] to save the configuration file. When the [No] button is clicked, settings will be cleared without saving.
4-4 Verifying the Configuration between PC and SL-V Current settings on the SL-V Configurator can be verified with the settings on the connected SL-V. 4 NOTE Other Functions 1 Settings can be verified only when the type configuration set in the [System Information] corresponds to the information uploaded to the connected SL-V. Click [Verify] on the toolbar. The settings list is displayed. 2 Click the [Next] button. Beam axes with Fix blanking or Muting enabled are displayed.
4-5 Monitoring the Received Light Intensity on the SL-V The received light intensity on each beam axis of the connected SL-V can be checked on the monitor of the PC. "Connecting" (Page 1-8) NOTE Click [Monitoring] on the toolbar. The received light intensity for each light axis is displayed. (1) (2) (3) (4) (5) (6) (7) (8) (9) Item 2 Function (1) Start Starts monitoring the received light intensity. (2) Stop Pauses monitoring the received light intensity.
4-6 Changing the Password The password used when uploading settings to the connected SL-V or initializing settings can be changed. Important Be sure to keep the password in a safe place and do not forget it. If you forget the password, configuration cannot be uploaded, initialized, or changed. NOTE • The password can be changed only when the SL-V is connected and you are logged in. "2-6 Login/Logout" (Page 2-10) • The password is the same as the one that is set using the input line of the SL-V.
4-7 Initializing the SL-V The connected SL-V can be initialized by uploading the factory default settings to the unit. NOTE • Settings can be initialized only when the SL-V is connected and you are logged in. "2-6 Login/Logout" (Page 2-10) • The password setting will not be changed. 4 Other Functions 1 Select [Restore to Factory Settings] from the [Configuration]. The [Warning] dialog box appears. 2 Click [OK]. When the settings have been changed, the save confirmation dialog box appears.
4-7 Initializing the SL-V 3 Click the [Next] button. The second page of the [Upload] dialog box appears. (The factory default settings are uploaded.) 4 Other Functions Important 4 Be sure to check the settings to be uploaded before clicking the [Accept] button. When unexpected settings are displayed, click the [Not Accept] button. When the [Not Accept] button is clicked, configurations are not set on the SL-V and the SL-V will not be started (It will go to lockout condition).
4-8 Outputting the Settings Settings can be output to paper or files so that they can be checked. Printing Perform the following procedures to print the settings. Select [Print] from the [File] menu. Other Functions 1 4 The [Print] dialog box appears. Item Select Printer Paper Options Function Name* Specifies the printer to be used. Preference* Sets the advanced settings for the printer. Paper Size* Sets the size of the paper. Orientation Sets the orientation of the paper.
4-8 Outputting the Settings 4 Other Functions Outputting in the CSV format To output the settings in CSV format, perform the following procedures. 1 Select [Export CSV File] from the [File] menu. The [Save As] dialog box appears. 2 Enter the file name and press the [Save] button. The CSV file is saved in the directory specified in the [Save in].
A Appendix SL-VH1S-NOA-E A-1 Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 A-2 Operation Menu List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 A-3 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A-1 Error Messages This section describes major error messages displayed during operations and the remedies when the messages are displayed. Error message A Appendix A-2 Cause Remedy Current SL-V system information mismatches the last upload settings. The last uploaded settings will be downloaded or be verified with. Continue? The system information sent to the SL-V main unit and the actual configuration of the SL-V is different. Check the configuration of the SL-V.
A-2 Operation Menu List File (F) Item Description Reference page 2-6 New (N) Creates new settings. [Shortcut key: Ctrl + N] Open (O) Opens the saved configuration file. [Shortcut key: Ctrl + O] Save (S) Saves the current settings over the old ones. [Shortcut key: Ctrl + S] Save As (A) Saves the current settings as a new file. 2-13 Export CSV File (V) Outputs the current settings as a CSV format file. 4-12 System Information (U) Changes the type information.
A-3 Index This index provides a list of terms used in this document. It is arranged in alphabetic order. A Alert Output ...................................................... 3-4 Appendix .......................................................... A-1 Authorization (R) ............................................... A-3 A B Appendix Basic Operation ............................................... 2-1 Before Use ....................................................... 1-1 Blanking Area ..................
A-3 Index Startup of the ................. 2-5 State Information Output .................................. 3-4 Status Bar ......................................................... 2-3 System Requirements ...................................... 1-4 T To read the existing configuration file .............. 2-7 Toolbar .............................................................. 2-2 A Appendix U Uninstalling the ..............
A-3 Index MEMO A Appendix A-6 SL-VH1S-NOA-E
A-3 Index MEMO A Appendix SL-VH1S-NOA-E A-7
Revision History Date Revision Revision contents November 2008 First December 2008 Second June 2009 Third Values changed in "EDM Function / Adjustment", etc. June 2010 Fourth Descriptions of "Windows 7 compatible" added, etc. September 2014 Fifth Notes added in "Connecting", etc.
WARRANTY KEYENCE products are strictly factory-inspected. However, in the event of a failure, contact your nearest KEYENCE office with details of the failure. 1. WARRANTY PERIOD The warranty period shall be for one year from the date that the product has been delivered to the location specified by the purchaser. 2. WARRANTY SCOPE (1) If a failure attributable to KEYENCE occurs within the above mentioned warranty period, we will repair the product, free of charge.