Instruction Manual

3-2 Non Safety Related Configuration
3-5
Configuration of Each Function
3
SL-VH1S-NO3-E
It cannot be configured to Built-in Indicator Mode when the muting bank function is enabled.
"3-4 Muting Area" (Page 3-7)
When the State Indicator Mode is set, normal operation is performed each time immediately after
the power is turned on. When OSSD ON state continues five seconds or more, the mode is
switched to the State Indicator Mode.
* Configuration of the State Indicator Mode
1 Select the State Indicator Mode, and click [Detail] button.
[Center Indicator] dialog is displayed.
2 Click [OK] button.
Configuration will be applied and it will return to the Main window.
Multiple lighting conditions cannot be assigned to a single state.
Center Indicator
Item
Contents of
Configuration
Description
Center Indicator Normal (Default) Normal operation is performed.
Built-In Indicator mode ON/OFF of the center indicator will be controlled by
external input.
OFF Center indicator will be constantly turned OFF.
State Indicator Mode* Lighting of the center indicator can be selected
depending on the state of the SL-V.
(When State-
Indicator Mode is
selected)*
Light in
red
OSSD OFF / WAIT input
active / None
Select the state to make the center indicator to turn on
in red.
Blinking
in green
Muting / Override /
WAIT input active / None
Select the state to make the center indicator to flash in
green.
Light in
green
OSSD ON / None Select the state to make the center indicator to turn on
in green.
Note
Item Description
(1) State Window This displays the state of the SL-V that can be assigned.
(2) Cancel Assign Button This will cancel the assigning selected in (4).
(3) Assign Button This will assign the state selected in (1).
(4) Lighting Condition This will display how it will be light.
(5) OK Button This will apply the configuration and close the dialog.
(6) Cancel Button This will not apply the configuration and close the dialog.
(1)
(4)
(6)(5)(3)(2)
Note