Instruction Manual
103
E SR-750 UM
How to decipher the SR-750 Series object table
Reading the object table (attribute)
Reading the object table (service)
Data type
The data types are defined as follows.
(1) (2) (3) (4)
Instance
ID
Attribute
ID
Name
Response parameter
Data
Typ e
Description
1
(0x01)
108
(0x6C)
IN/OUT
Status
UINT
bit0: IN1 Status
bit1: IN2 Status
bit4: OUT1 Status
bit5: OUT2 Status
bit6: OUT3 Status
Item Description
(1) Instance ID The instance ID is shown in decimal (hexadecimal).
(2) Attribute ID The attribute ID is shown in decimal (hexadecimal).
(3) Name Denotes the attribute name.
(4) Response
parameter
Displays the receiving parameter's data type and each parameters
description.
(1) (2) (3) (4) (5)
Instance
ID
Service
code
Service data
Name Description
Data
type
Data
1
(0x01)
0x4B UINT
Bank
Number
Read
Start
Starts reading.
Item Description
(1) Instance ID The instance ID is shown in decimal (hexadecimal).
(2) Service code The service code is shown in decimal (hexadecimal).
(3) Service data Displays the type of the service data and service data description.
(4) Name Displays the service name.
(5) Description Displays the service function description.
Data type Description
Range
Min. Max.
BOOL Boolean 0: FALSE 1: TRUE
SINT Short integer -128 127
INT Integer -32768 32767
DINT Double precision integer -2
31
2
31
-1
LINT Long integer -2
63
2
63
-1
USINT Unsigned short integer 0 255
UINT Unsigned integer 0 65535
UDINT Unsigned double precision integer 0 2
32
-1
ULINT Unsigned long integer 0 2
64
-1
String String (1 byte/character) - -
SSTRING String (1 byte/character) - -
BYTE Bit sequence: 8-bit - -
WORD Bit sequence: 16-bit - -
DWORD Bit sequence: 32-bit - -
LWORD Bit sequence: 64-bit - -
SR-750 Series Object Details
This section describes the SR-750 Series object configuration.
SR AutoID Reader Object (Class ID: 105 (0x69))
This object delivers the SR-750 Series connected status and device writing/
reading.
This is an object specific to the SR-750 Series.
Attributes
The SR AutoID Reader Object supports the following attributes.
Instance
ID
Attribute
ID
Name
Response parameter
Data Description
1
(0x01)
100
(0x64)
Read Status
UINT
bit0 : Error
bit1 : Result Data Available
bit2 : Result Data Strobe
bit3 to 5 : Reserved
bit6 : Buffer Overflow Error
bit7 : General Error
bit8 : BUSY
bit9 : TRG BUSY
bit10 : LOCK BUSY
bit11 : MODE BUSY
bit12 : ERR BUSY
bit13 : FILE BUSY
bit14 to 15 : Reserved
UINT
bit0 : Read Complete
bit1 : Read Failure
UINT
bit0 : Unstable
bit1 : Matching Level Unstable
bit2 : ISO/IEC 15415 Unstable
bit3 : AIM DPM Unstable
bit4 : SAE AS9132 Unstable
UINT Read Result Code
101
(0x65)
Preset Status
UINT
bit0 : Error
bit1 : Result Data Available
bit2 : Result Data Strobe
bit3 to 5 : Reserved
bit6 : Buffer Overflow Error
bit7 : General Error
bit8 : BUSY
bit9 : TRG BUSY
bit10 : LOCK BUSY
bit11 : MODE BUSY
bit12 : ERR BUSY
bit13 : FILE BUSY
bit14 to 15 : Reserved
UINT
bit0 : Preset Complete
bit1 : Preset Failure
bit2 to 15 : Reserved
UINT Reserved
UINT Preset Result Code
102
(0x66)
Register Preset
Data Status
UINT
bit0 : Error
bit1 : Result Data Available
bit2 : Result Data Strobe
bit3 to 5 : Reserved
bit6 : Buffer Overflow Error
bit7 : General Error
bit8 : BUSY
bit9 : TRG BUSY
bit10 : LOCK BUSY
bit11 : MODE BUSY
bit12 : ERR BUSY
bit13 : FILE BUSY
bit14 to 15 : Reserved
UINT
bit0 :
Register Preset Data Complete
bit1 :
Register Preset Data Failure
bit2 to 15 : Reserved
UINT Reserved
UINT Register Preset Data Result Code
103
(0x67)
Tune Status
UINT
bit0 : Error
bit1 : Result Data Available
bit2 : Result Data Strobe
bit3 to 5 : Reserved
bit6 : Buffer Overflow Error
bit7 : General Error
bit8 : BUSY
bit9 : TRG BUSY
bit10 : LOCK BUSY
bit11 : MODE BUSY
bit12 : ERR BUSY
bit13 : FILE BUSY
UINT
bit0 : Tune Complete
bit1 : Tune Failure
bit2 to 15 : Reserved
UINT Reserved
UINT Tune Result Code