Instruction Manual
104
E SR-750 UM
1
(0x01)
107
(0x6B)
EXT. Request
Status
UINT
bit0 : Error
bit1 : Result Data Available
bit2 : Result Data Strobe
bit3 to 5 : Reserved
bit6 : Buffer Overflow Error
bit7 : General Error
bit8 : BUSY
bit9 : TRG BUSY
bit10 : LOCK BUSY
bit11 : MODE BUSY
bit12 : ERR BUSY
bit13 to 15 : Reserved
UINT
bit0 : EXT. Request Complete
bit1 : EXT. Request Failure
bit2 to 15 : Reserved
UINT
bit0 : Unstable
bit1 : Matching Level Unstable
bit2 : ISO/IEC 15415 Unstable
bit3 : AIM DPM Unstable
bit4 : SAE AS9132 Unstable
UINT EXT. Request Result Code
108
(0x6C)
IN/OUT Status UINT
bit0 : IN1 Status
bit1 : IN2 Status
bit2 to 3 : Reserved
bit4 : OUT1 Status
bit5 : OUT2 Status
bit6 : OUT3 Status
bit7 to 15 : Reserved
109
(0x6D)
Statistics
UINT Read (Comparison) OK Count
UINT Comparison NG Count
UINT Read Error Count
UINT Stable Reading Count
UINT Read Input Count
UINT Reserved
110
(0x6E)
Result Data Count
UINT Result Data Ready Count
UINT Result Data Update Count
111
(0x6F)
General Error Code UINT General Error Code
112
(0x70)
Read (Comparison)
OK Count
UINT Read (Comparison) OK Count
113
(0x71)
Comparison NG
Count
UINT Comparison NG Count
114
(0x72)
Read Error Count UINT Read Error Count
116
(0x74)
Read Input Count UINT Read Input Count
128
(0x80)
Result Data Ready
Count
UINT Result Data Ready Count
129
(0x81)
Result Data Update
Count
UINT Result Data Update Count
Instance
ID
Service
code
Attribute
ID
Name
Response parameter
Data Description
1
(0x01)
Get_
Attribute_
Single
14
(0x0E)
144
(0x90)
Unstable Inspect
Configuration
UINT
bit0 : Matching Level
Inspect Valid
bit1 : ISO/IEC15415
Inspect Valid
bit2 : AIM DPM
Inspect Valid
bit3 : SAE AS9132
Inspect Valid
bit4 to 7 : Reserve
Set_
Attribute_
Single
16
(0x10)
145
(0x91)
Matching Level
Threshold
UINT 99 to 00
146
(0x92)
ISO/IEC15415
Threshold
UINT
0: Disabled
1(D) to A(4)
147
(0x93)
AIM DPM
Threshold
UINT
0: Disabled
1(D) to A(4)
Get_
Attribute_
Single
14
(0x0E)
152
(0x98)
Matching Level UINT 100 to 00
153
(0x99)
ISO/IEC15415
Grade
UINT 4(A) to 0(F)
154
(0x9A)
AIM DPM Grade UINT 4(A) to 0(F)
Instance
ID
Attribute
ID
Name
Response parameter
Data Description
Service
The SR AutoID Reader Object supports the following services.
Identity Object (Class ID: 1 (0x01))
This object is used to acquire equipment information.
The SR-750 Series offers the hardware reset service.
Service
The Identity Object supports the following services.
Instance
ID
Service
code
Service data
Name Description
Data type: Data
1
(0x01)
14
(0x0E)
-
Get_Attribute
_Single
Obtains the attribute's one item.
16
(0x10)
-
Set_Attribute_
Single
Obtains the attribute's one item.
75
(0x4B)
UINT: Bank
Number
Read Start Starts reading.
76
(0x4C)
- Read Stop Stops reading.
77
(0x4D)
- Preset Start Starts preset data reading.
78
(0x4E)
- Preset Stop Stops preset data reading.
79
(0x4F)
UINT: Preset
Data Size
BYTE[]:
Preset Data
Register
Preset Data
Registers preset data.
Preset data can be deleted when Size is
(1) and Data is (0xFF).
80
(0x50)
- Tune Start Starts calibration.
81
(0x51)
- Tune Stop Stops calibration.
83
(0x53)
- Error Clear Clears the error.
84
(0x54)
-
EXT. Request
Complete
Clear
Clears the operation status from the
external command.
85
(0x55)
UINT: Result
Data Size
UINT: Offset
Get Result
Data
Acquires read data.
Response data
UINT : Result Data Size
UINT : Rest Result Data Size
BYTE[] : Result Data
86
(0x56)
-
Sequence
Reset
Clears the following information:
• Result Data Ready Count
• Result Data Update Count
• Main unit statistical information
• Buffering data
• Sequence bit
87
(0x57)
- Lock Sets the operation lock command.
88
(0x58)
- Unlock Sets the operation unlock command.
90
(0x5A)
-
Read
Complete
Clear
Clears the Read Complete and Read
Failure bits.
91
(0x5B)
-
Preset
Complete
Clear
Clears the Preset Complete and Preset
Failure bits.
92
(0x5C)
-
Register
Preset Data
Complete
Clear
Clears the Register Preset Data
Complete and Register Preset Data
Failure bits.
93
(0x5D)
-
Tune
Complete
Clear
Clears the Tune Complete and Tune
Failure bits.
Instance
ID
Service
code
Service data
Name Description
Data (
Data type)
1
5
(0x05)
- Reset Performs hardware reset.