Instruction Manual

108
E SR-750 UM
[Message communication] Hardware reset processing
This is a reference program for hardware reset (restart) in message
communication.
For the KV Series
Reference program chart
For the Control Logix/Compact Logix (RSLogix 5000)
Reference program chart
For the Micro Logix (RSLogix 500)
Reference program chart
Point
With this operation, the software reset operation can be performed
for the SR-750.
This operation returns the SR-750 Series to the state when the
power is turned on.
This operation cannot be performed in cyclic communication.
REQ
R30700
REQ
#0
U_MSGTO KV-5500
#0
U_MSGTO KV-5500
DM100
DM0
R30700
Message communication
start request
R30700
Message communication
start request
R31700
Message communication
complete
' Data are stored using the box script.
' Data can also be stored with the MOV command.
DM0 = 192 ' IP address the first byte (arbitrary)
DM1 = 168 ' IP address the second byte (arbitrary)
DM2 = 100 ' IP address the third byte (arbitrary)
DM3 = 100 ' IP address the fourth byte (arbitrary)
DM4 = 5 ' service cord (0x05)
DM5 = 1 ' class ID (0x01)
DM6 = 1 ' instance ID (0x01)
DM7 = 0 ' attribute ID (0x00)
DM100 = 0 ' Sent data in message communication
R30700
Message communication
start request
Unit No.
Message
communication
Unit No.
Message
communication
( EN )
( DN )
( ER )
ONS
Service Type Custom
Service Code 5(Hex)
Class 1(Hex)
Instance 1
Attribute 0
Source Element -
Source Length -
Destination -
MSG
( EN )
( DN )
( ER )
ONS
Communication Command CIP Generic
Size in byte(Receive) 0
Data Table Address(Receive) -
Size in byte(Send) 0
Data Table Address(Send) -
Service Custom
Service Code 5(Hex)
Class 1(Hex)
Instance 1
Attribute 0
MSG