E SR-750 UM
SAE AS9132 verification
Sets SAE AS9132 verification function.
Default : Disable
Setting range : Disable or Enable
SAE AS9132 verification threshold
Sets the threshold of SAE AS9132 evaluation result.
Default : Disable
Setting range : Disable or Enable
SEMI T10-0701 verification
Sets SEMI T10-0701 verification function.
Default : Disable
Setting range : Disable or Enable
Select expression of grades
Set this option to select expression of quality grades.
Default : Alphabet
Setting range : Alphabet or Numeric
Append detailed verification result
Sets the detailed verification result addition function when the verification result is
appended.
Default : Disable
Setting range : Disable or Enable
Append values
Sets the evaluation value addition function when the verification result is
appended.
Default : Disable
Setting range : Disable or Enable
Edit Data
Data edit by script
Sets the edit data function.
Default : Disable
Setting range : Disable or Enable
Additional Data
•Time
Set this option to append time.
Default : Disabled
Setting range : Disable or Enable
Detail error code
Set the additional function for detailed read code.
Default : Disable
Setting range : Disable or Enable
Code type
Set this option to append code type.
Default : Disabled
Setting range : Disable or Enable
Symbol ID
Set this option to append symbol ID.
Default : Disabled
Setting range : Disable or Enable
Parameter bank
Set this option to append bank number.
Default : Disabled
Setting range : Disable or Enable
Burst number
Sets the additional function for burst number.
Default : Disable
Setting range : Disable or Enable
Read count
Set this option to append scan count.
Default : Disabled
Setting range : Disable or Enable
Position level
Set this option to append position measurement level.
Default : Disabled
Setting range : Disable or Enable
Code vertex
Set this option to append corner coordinates of codes.
Default : Disabled
Setting range : Disable or Enable
Code center
Set this option to append center coordinates of codes.
Default : Disabled
Setting range : Disable or Enable
ECC level (UEC)
Set this option to append unused ECC ratio.
Default : Disabled
Setting range : Disable or Enable
Matching level
Set this option to append matching level.
Default : Disabled
Setting range : Disable or Enable
ISO/IEC15415 verification result
Set threshold of ISO/IEC15415 verification result.
Default : Disable
Setting range : Disable or Enable
ISO/IEC TR 29158 (AIM DPM-1-2006) verification result
Sets ISO/IEC TR 29158 (AIM DPM-1-2006) verification result addition function.
Default : Disable
Setting range : Disable or Enable
SAE AS9132 verification result
Sets SAE AS9132 verification result addition function.
Default : Disable
Setting range : Disable or Enable
SEMI T10-0701 verification result
Default : Disable
Setting range : Disable or Enable
Image file name
Set this option to append image name.
Default : Disabled
Setting range : Disable or Enable
Read time
Sets the read time function.
Default : Disabled
Setting range : Disable or Enable
•Group name
Sets the additional function for the group name used in the Master/Slave
function.
Default : Disable
Setting range : Disable or Enable
Master/Slave ID
Sets the additional function for Master/Slave ID.
Default : Disable
Setting range : Disable or Enable
Comparison
Comparison method
Sets the comparison method.
Default : Normal
Setting range : Normal or Sequential
•Origin
Sets the origin of comparison or preset.
Default : 1
Setting range : 1 to 7089
•Length
Sets the length for comparison or preset.
Default : 494
Setting range : Normal …0 to 494
Sequential …0 to 9
Increment
When the comparison method is Sequential, set the increment.
Default : 1
Setting range : - 9999 to 9999
Preset data
Registers the preset data.
Default : Not selected
Setting range : Enter up to 494 ASCII or hexadecimal characters.