I/O
Input Terminal Common
Input polarity
Sets the input polarity of the IN terminal.
Default : Norm. open
Setting range : Norm. open or Norm. close
Required input duration
Sets the required input duration for the IN terminal.
Default : 2 ms
Setting range : 1 ms, 2 ms, or 10 ms
IN1/2 Terminal
Function
Sets the function for the IN1/2 terminal.
Default : IN1 terminal…Timing input
IN2 terminal…Preset input
Setting range : Disable, TIMING, Preset Input, TEST, Clear PLC link error,
TUNING
Test mode
When "TEST" is selected, specify the test mode to start.
Default : Reading rate test
Setting range : Reading rate test, Read time test, or Positioning test
Startup state
Sets whether to activate the input function specified for the IN1 and IN2 terminals
at power-on.
Default : Disable
Setting range : Disable or Enable
IN LED synchronization
Set whether to synchronize with IN LED.
Default : IN1…Enable
IN2…Disabled
Setting range : Disable or Enable
Output Terminal
TRG BUSY Output at Power On
Set this option to enable TRG BUSY output upon reader startup.
Default : Enable
Setting range : Disable or Enable
Output duration
Sets the output ON duration for the OUT terminal.
Default : 500 ms
Setting range : 10 to 2550 ms
OUT1/2/3 function
Sets the function for the OUT1/2/3 terminal.
Default OUT1…OK
OUT2…NG (Comparison NG), ERROR
OUT3…TRG, LOCK, MODE, ERR BUSY
Setting range : OK, NG (Comparison NG), ERROR, STABLE, UNSTABLE,
PRESET OK, TUNING OK, TRG BUSY, LOCK BUSY, MODE
BUSY, ERR BUSY, FILE BUSY or EXT.LIGHT
External light output polarity
Sets the output polarity of the EXT.LIGHT signal.
Default : Norm. open
Setting range : Norm. open, Norm. closed
Saving Images
•OK image
Sets the saving option for images successfully read.
Default : Disabled
Setting range : Disabled or Send by FTP
•Comparison NG
Set save destination for comparison NG image.
Default : Disable
Setting range : Disabled or Send by FTP
•Error image
Sets the save destination for read error images.
Default : Save to RAM
Setting range : Disabled, Save to RAM, Save to ROM, or Send by FTP
Unstable image
Sets the save destination for unstable images.
Default : Disable
Setting range : Disabled or Send by FTP
Target burst number
Default : All banks
Captured image
Sets the saving option for captured images.
Default : Save to RAM
Setting range : Save to RAM or Send by FTP
Image Save Mode
Sets the image saving mode.
Default : Save final bank image
Setting range : Save final bank image, Save specified number of images after
timing ON, or Save specified number of images after timing OFF
Number of images to save
Sets the number of images to save after the timing ON/OFF.
Default : 10 images
Setting range : 1 to 10 images
Edit image file name by script (FTP transmission only)
Sets the edit image file name function.
Default : Disable
Setting range : Disable or Enable
FTP Settings
IP address
Sets the IP address of the remote FTP server.
Default : 0.0.0.0
Setting range : 0.0.0.0 to 255.255.255.255
User/Password
Sets the user name/password of the destination required for FTP client
operations.
Default : User…admin
Password…admin
Setting range : Up to 16 characters
Set in ASCII characters.
Passive mode
Set this option to send passive commands to the remote FTP server.
Default : Disable
Setting range : Enable or Disable
Change directory
Set this option to change FTP remote directory.
Default : Disabled
Setting range : Disable or Enable
Format
Sets the image format sent via FTP.
Default : JPEG
Setting range: JPEG, Bitmap
JPEG quality
Default : 5
Setting range : 1 to 10
Binning
Default : 1/4
Setting range: Full, 1/4, 1/16, 1/64
Directory name
Sets the remote directory.
Default : image
Setting range : 1 to 32 characters