Instruction Manual
64
E SR-750 UM
Appending Data
Various types of data can be appended to read data.
Read data format
The data format for appending various types of data to read data is shown below:
Delimiter characters
• The colon (:) as a delimiting character can be changed via AutoID Network
Navigator (one character).
• No delimiter character is inserted after "Data size" and "Symbol ID", and before
"Checksum".
Precautions when appending data
• Appended data can be set via a command or from AutoID Network Navigator.
• Only the selected data will be appended to the read data. The data size changes
because of this.
• Checksum defers by the contents of the appended data.
Details of Appended Data
Data size
The data size is the total size of parts (1), (2), and (3), plus 4 bytes.
Time
Appends the time the data was output.
Appended data range: YYYYMMDDhhmmss
• Data format
Read detailed error code
Factors that caused read errors are judged for each burst number.
The Read detailed error code is appended before the Read data.
n: Maximum value of the burst No.
• The detailed error code is appended starting with burst No. 1.
• The detailed error code is appended with the following contents.
Code type
The type of read code can be appended before the read data.
Data
size
Time
:
Detail error
code
:
Code
type
:
Symbol
ID
Read
data
:
Parameter
bank
numbers
:
Burst
number
:
Scan
count
:
Positioning
level
:
Code vertex
coordinates
:
Code center
coordinates
:
Unused
ECC
ratio
:
Matching
level
:
ISO/IEC15415
verification
result
:
ISO/IEC TR 29158
(AIM DPM-1-2006)
verification result
:
SAE AS9132
verification
result
:
SEMI T10-0701
verification
result
:
Image
file name
:
Group
name
:
Master/
Slave ID
:
Read
time
Check-
sum
YYYYMMDDhhmms : Read data
Burst number 1
detailed error code
:
Burst number 2
detailed error code
:…:
Burst number n
detailed error code
:
Read data
Detailed error code Description
0 Reading success
1 No code
2 The set decode timeout period elapsed.
3 Scanning aborted.
9 Reading images failed.
Code type ID Read data
0 Reading error
1QR
2 DataMatrix
5 GS1 DataBar
6CODE39
7ITF
9 NW-7(Codabar)
10 JAN/EAN/UPC
11 CODE128
(3)(2)(1)
Header
Data size Read data + appended data
Termi-
nator
Checksum
Symbol ID
Appends the symbology identifier, specified by AIM, before the read data.
It is not appended when a reading has failed.
• Data format
Parameter bank number
Appends the parameter bank number that was read.
It is not appended when a reading fails.
• Data format
nn = parameter bank number (01 - 10)
Burst number
Outputs the burst number of the successfully read image in the burst read mode.
No data is appended for a failed reading.
This data is not appended in any mode other than the burst read mode.
• Data format
n = burst number (1 - 8)
Scan count
Appends the number of reading attempts of the SR-750 Series while the timing
input is turned ON.
Failed reading operations are also counted.
• Data format
nnnnn = scan count (1 - 65535)
Position level
Appends the position level of the read code.
When several codes are read for one scan (multi read), the average of all code
position levels is output.
0 is appended when a reading fails.
• Data format
n = position level value (0 - 5)
Symbol ID Read data
Code type Detail Symbol ID
QR : Model 1 ]Q0
: Model 2, ECI not applied ]Q1
: Model 2, ECI applied ]Q2
: Model 2, ECI not applied, FNC1 (1st) ]Q3
: Model 2, ECI applied, FNC1 (1st) ]Q4
: Model 2, ECI not applied, FNC1 (2nd) ]Q5
: Model 2, ECI applied, FNC1 (2nd) ]Q6
DataMatrix : ECC 200 ]d1
: ECC 200, FNC1 (1st) ]d2
: ECC 200, FNC1 (2nd) ]d3
: ECC 200, ECI applied ]d4
: ECC 200, ECI applied, FNC1 (1st) ]d5
: ECC 200, ECI applied, FNC1 (2nd) ]d6
CODE39 No check digit validation ]A0
Check digit is validated and transmitted. ]A1
Check digit is validated but not transmitted. ]A3
ITF No check digit validation ]I0
Check digit is validated and transmitted. ]I1
Check digit is validated but not transmitted. ]I3
NW-7(Codabar) ]F0
JAN/EAN/UPC UPC-A, UPC-E, JAN/EAN13 ]E0
JAN/EAN8 ]E4
UPC-A, UPC-E, JAN/EAN13
Addon 2, addon 5
]E3
CODE128 FNC1 not included. ]C0
FNC1 on the first digit (GS1-128). ]C1
FNC1 on the second digit. ]C2
GS1 Databar ]e0
Read data : nn
Read data : n
Read data : nnnnn
Read data : level = n