Instruction Manual

74
E SR-750 UM
Forced trigger lock release
Send command UNLOCK
Response Normal process OK, UNLOCK
Abnormal process ER, UNLOCK, ee ee: Error code
Releases trigger lock.
Obtaining forced trigger lock status
Send command RLOCK
Response OK, RLOCK, nnnn
nnnn = forced trigger lock status
"LOCK" or "UNLOCK" is added.
Laser Pointer Control
The laser pointer for confirming a code position lights up or lights off using a
command.
Laser Pointer ON
Send command LDON
Response Normal process OK, LDON
Abnormal process ER, LDON, ee ee: Error code
Laser Pointer OFF
Send command LDOFF
Response Normal process OK, LDOFF
Abnormal process ER, LDOFF, ee ee: Error code
Tuning
Starting tuning
Send command TUNE, bb
Response OK, TUNE
bb = 01 to 10: Reading bank number: 1 to 10
When tuning operation is complete, the result is output in the following formats.
Success : Tuning SUCCEEDED,Tms,00000x00
Failure : Tuning FAILED,Tms,00000x0y
Tms: Tuning time
x: Advice 0,1,2,4 0: No advice
1: Filter process change may be enabled.
2: Installation condition, lighting condition or marking
condition adjustments should be considered.
4: Brightness may be insufficient.
y: Failure factor 1,2 1: Code detection impossible
2: Unstable reading
Tuning process starts.
When tuning is successful, the result is saved to the specified bank (also saved
to the ROM).
Finishing tuning
Send command TQUIT
Response OK, TQUIT
Tuning process finishes.
Obtaining the alternate order
Send command BANKORDER
Response Normal process OK, BANKORDER, bb/bb/bb/· · ·
bb: parameter bank number (01 - 10)
Abnormal process
ER, BANKORDER, ee
ee: Error code
The parameter bank numbers to alternate are returned in turn.
The parameter bank numbers are returned with the number of parameter bank
numbers registered with the SR-750 Series. (max. 16)
If there is no parameter bank number to alternate, an error is returned.
If Specify response character is set to "SR-600 compatible", bb/bb/bb· · ·
is returned for normal process and ERRee is returned for abnormal process.
"3-9 SR-600 Compatible Output Mode (Page 19)"
Initializing the parameter bank
Send command BANKCLR, bb bb:
parameter bank number (00 - 10)
00 =
Initialize all parameter banks
01 - 10 = Initialize specified
parameter banks only
Response Normal process OK, BANKCLR
Abnormal process ER, BANKCLR, ee ee: Error code
If Specify response character is set to "SR-600 compatible", OK is returned for
normal process and ERRee is returned for abnormal process.
"3-9 SR-600 Compatible Output Mode (Page 19)"
Other Commands
Save settings
Send command SAVE
Response Normal process OK, SAVE
Abnormal process ER, SAVE, ee ee: Error code
The SAVE command is sent to save in the memory the setting contents sent to
the SR-750 Series.
The command setting is applied after the response of the SAVE command is
sent.
Obtaining configuration command status
Send command CMDSTAT
Response OK, CMDSTAT, nnnn
nnnn = none : No operation
wait : Wait for the setting applied
update : Program updating
Command to obtain configuration change status. This is used to check the
process status of a configuration command such as WN, WP, and WB.
If Specify response character is set to "SR-600 compatible", nnnn is returned.
"3-9 SR-600 Compatible Output Mode (Page 19)"
Setting initialization
Send command DFLT
Response Normal process OK, DFLT
Abnormal process ER, DFLT, ee ee: Error code
Resets the SR-750 Series to the default configuration.
When the SR-600 compatible output mode is "Enabled", OK and ERRee are
returned for normal process and abnormal process respectively.
"3-9 SR-600 Compatible Output Mode (Page 19)"
When executing the script file - status confirmation
command
Obtaining the script processing time
Send command SCPTIME
Response OK, SCPTIME, now=AAus, max=BBus, min=CCus
AA: Returns the most recent script processing time.
BB: Returns the maximum value of the processing time.
CC: Returns the minimum value of the processing time.
Returns the processing time of script executed after power ON.
Script debug setting
Send command SCPDBG, n
Response OK, SCPDBG
n=0: Script debug OFF
n=1: Script debug ON
Sets whether to output debug from the script file to the command port or not.
Setting the debug ON executes print(str) and outputs data.
Obtaining the script error results
Send command SCPERR
Response OK, SCPERR, mmmmmmmmmmmmmmmmmmmmmmmmmmmmmm
mm… : Script error character string
Returns the details of script error.