Instruction Manual
78
E SR-750 UM
NW-7 (Codabar)
settings
0900 03 to 50 Maximum read length 50
0901 03 to 50 Minimum read length 4
0902 4 to 11 Quiet zone scale factor 7
0903 0,1
Send start/stop characters
0 : Disable
1:Enable
1
0904 0,1
Send start/stop characters letter
type
0 : as lowercase
1 : as UPPERCASE
0
0905 0,1
Inspect check-digit
0 : Disable
1:Enable
0
0906 0,1
Send check-digit
0 : Disable
1:Enable
1
0907 0 to 6
Check-digit type
0:Modulus 16
1:Modulus 11
2 : Modulus 10/Weight 2
3 : Modulus 10/Weight 3
4 : Check DR
5 : Modulus 11-A
6:Luhn
0
JAN/EAN/UPC settings
1002 4 to 11 Quiet zone scale factor 7
1003 0,1
UPC-E reading
0 : Disable
1:Enable
1
1004 0,1
EAN/JAN 8 digits reading
0 : Disable
1:Enable
1
1005 0,1
EAN/JAN 13 digits reading
0 : Disable
1:Enable
1
1006 0,1
UPC-A Output
0 : Output in 13 digits
1 : Output in 12 digits
0
1007 0,1
Add "number system" to UPC-E
0 : Disable
1:Enable
0
1008 0,1
2-digit supplemental
0 : Disable
1:Enable
1
1009 0,1
5-digit supplemental
0 : Disable
1:Enable
1
1010 0,1
Ignore UPC without supplemental
0 : Disable
1:Enable
0
1011 0,1
GTIN compatible 14-digit output
0 : Disable
1:Enable
0
CODE128
1100
001 to 128
Maximum read length 128
1101
001 to 128
Minimum read length 1
1102 4 to 11 Quiet zone scale factor 7
1103 0,1
GS1-128
0 : Disable
1:Enable
1
Function
Command
Number
Setting
value
Explanation Default
Operation Configuration Command Format (WP/RP)
Operation configuration command is sent in the following format:
• Configuration change
Send command
Response Normal process
Abnormal process
• Configuration confirmation
Send command
Response Normal process
Abnormal process
mmm : Command number Fixed to 3 bytes
nnn… : Setting value (varies according to command number)
example) When setting the trigger input measurement method to "One-shot
trigger" (one-shot signal trigger)
Configuration change Send command WP, 101, 1
Response (Normal process) OK, WP
Configuration confirmation Send command RP, 101
Response (Normal process) OK, RP, 1
I/O terminal setting
Function
Command
Number
Setting
value
Explanation Default
IN
terminal
setting
IN1 terminal
function
000 0 to 8
0:Not use
1 : Trigger input
2 : Preset Input
3 : Start test mode.
5 : Clear PLC link error
8 : Tuning operation
1
IN2 terminal
function
001 0 to 8
0:Not use
1 : Trigger input
2 : Preset Input
3 : Start test mode.
5 : Clear PLC link error
8 : Tuning operation
2
IN1 terminal
test mode
assignment
002 1 to 3
1 : Reading rate test
2 : Processing time test
3 : Position test
1
IN2 terminal
test mode
assignment
003 1 to 3
1 : Reading rate test
2 : Processing time test
3 : Position test
1
IN1 terminal
input at
power-on
006 0, 1
0:Not use
1:Enable
0
IN2 terminal
input at
power-on
007 0, 1
0:Not use
1:Enable
0
Synchronizat
ion of IN1
and TIMING
LED
008 0, 1
0 : Disable
1:Enable
1
Synchronizat
ion of IN2
and TIMING
LED
009 0, 1
0 : Disable
1:Enable
0
Input polarity 010 0, 1
0 : Normal open point
1 : Normal close point
0
Input pulse
width
011 0 to 2
0:1 ms
1:2 ms
2:10 ms
0
WP , mmm , nnn…
OK , WP
ER , WP , ee ee: Error code
RP , mmm
OK , RP , nnn…
ER , RP , ee ee: Error code