Owner's manual

5-7
Setting Each Function
Setting Items
- Setup software TM-H1 TM-Navigator User’s Manual -
Master image registration window
Setting items Description
(1) Capture image This captures images of Head A and Head B from the controller.
(2) Trigger When the "External trigger" is set for "Trigger settings" in "Head setting", a trigger
is input by clicking the [Trigger] button.
(3) Register head A This registers (4) "Head-A Update image" as a master image.
(4) Head-A Update image This displays the image of Head A captured from the controller.
(5) Head-B Update image This displays the image of Head B captured from the controller.
(6) Head-A Master image This displays the set master image of Head A.
(7) Head Alignment This displays the head alignment window for Head A.
"Head alignment window" (page 5-8)
(8) Head-B Master image This displays the set master image of Head B.
(9) Head Alignment This displays the head alignment window for Head B.
"Head alignment window" (page 5-8)
(10) Register head B This registers (5) "Head-B Update image" as a master image.
(11) OK This confirms the set contents and closes the window.
(12) Cancel This cancels the set contents and closes the window.
(1)
(5)
(10)
(6)
(2) (3)
(4)
(7)
(8)
(9)
(11) (12)