Datasheet
This information is subject to change without notice.
© Keysight Technologies, 2014 - 2018
Published in USA, January 10, 2018
www.keysight.com
Keysight | AC6800B and 6800B Series Basic and Performance AC Power Sources – Product Fact Sheet
For more information on Keysight AC Power Sources, please visit:
www.keysight.com/find/ACSources
To find a distributor in your area, go to: www.keysight.com/find/distributors
5991-4036EN
Accessories and options
AC6800B Series Basic AC Sources
Model
number
Description
AC68GPBU Upgrade user installable GPIB
interface board for AC6800
Series AC sources
AC68BALGU Upgrade user installable analog
interface board for AC6800B
Series AC sources
AC68BRAC3 Rack mount kit for AC6801B,
AC6802B, AC6803B (flanges
only)
AC68BRAC6 Rack mount kit for AC6804B
(flanges only)
6800C Series Performance AC Sources
020 Dual Power Analyzer for 6811C,
6812C, 6813C
026 26 Volt, 0.1A, auxiliary reference
input for 6812C, 6813C
019 Output raised to 2000VA,
frequency reduced to 100Hz for
6813C
Product specifications
AC6800B Series 6800C Series
Basic AC Sources Performance AC Sources
AC6801B AC6802B AC6803B AC6804B 6811C 6812C 6813C
Phases Single-phase
Maximum output Power 500 VA 1000 VA 2000 VA 4000 VA 375 VA 750 VA 1750 VA
AC output mode
Voltage range 155 Vrms / 310 Vrms 300 Vrms
Voltage setting accuracy 0.3%/0.25% full-scale 45 to 100 Hz: 0.15% + 0.3 V
> 100 to 500 Hz: 0.5% + 0.3 V
> 500 to 1000 Hz: 1% + 0.3 V
Maximum rms current 5 A/2.5 A 10 A/5 A 20 A/10 A 40 A/20 A 3.25 A 6.5 A 13 A
Maximum peak current 15 A/7.5 A 30 A/15 A 60 A/30 A 120 A/60 A 40 A 40 A 80 A
Frequency 500 Hz 1 kHz
Measurements Voltage, current, power
Transients & Advanced
Measurements
N/A
Note: Basic transient capability via Optional Analog card (AC68BALGU)
Includes pre-programmed standard waveforms and
transient generation system
DC output mode
Voltage range 190 V/380 V 425 VA
Max current 4 A/2 A 8 A/4 A 16 A/8 A 32 A/16 A 2.5 A 5.0 A 10.0 A
Maximum instantaneous
current
12 A/6 A 24 A/12 A 48 A/24 A 96 A/48 A 40 A 40 A 80 A
Power capacity 400 W 800 W 1600 W 3200 W 285 W 575 W 1350 W
I/O
LAN/LXI-Core with remote web interface
USB
Optional: GPIB
LAN/LXI-Core with remote web interface
USB
GPIB
Keysight Assurance Plans
www.keysight.com/find/AssurancePlans
Up to ten years of protection and no budgetary surprises to ensure your
instruments are operating to specification, so you can rely on accurate