Datasheet
06 | Keysight | 6800C Series AC Power Source/Analyzers, 375-1750 VA - Data Sheet
Specifications
(at 0 ° to 40 °C unless otherwise
specified)
6811C 6812C 6813C
Number of phases 1 1 1
Output ratings (Maximum)
Power 375 VA 750 VA 1750 VA
rms voltage 300 V 300 V 300 V
rms current 3.25 A 6.5 A 13 A
Repetitive & non-repetitive peak current 40 A 40 A 80 A
Crest factor 12 6 6
Load power factor capability 0 to 1 0 to 1 0 to 1
DC power 285 W 575 W 1350 W
DC voltage ± 425 VA ± 425 V ± 425 V
DC current 2.5 A 5.0 A 10.0 A
Output frequency range
1
DC; 45 Hz to 1 kHz DC; 45 Hz to 1 kHz DC; 45 Hz to 1 kHz
Constant voltage ripple and noise
(20 kHz to 10 MHz)
–60 dB
(relative to full scale)
–60 dB
(relative to full scale)
–60 dB
(relative to full scale)
Line regulation (% of full scale) 0.1% 0.1% 0.1%
Load regulation (% of full scale) 0.5% 0.5% 0.5%
Maximum total harmonic distortion 0.25% at 50/60 Hz 0.25% at 50/60 Hz 0.25% at 50/60 Hz
1% worst case 1% worst case 1% worst case
45 to 1 kHz 45 to 1 kHz 45 to 1 kHz
Programming accuracy (at 25 ° ± 5 °C) 6811C 6812C 6813C
RMS voltage (% of output + offset) 45 to 100 Hz
0.15% + 0.3 V
>100 to 500 Hz
45 to 100 Hz
0.15% + 0.3 V
>100 to 500 Hz
45 to 100 Hz
0.15% + 0.3 V
>100 to 500 Hz
0.5% + 0.3 V
>500 to 1000 Hz
0.5% + 0.3 V
>500 to 1000 Hz
0.5% + 0.3 V
>500 to 1000 Hz
1% + 0.3 V 1% + 0.3 V 1% + 0.3 V
DC voltage 0.1% + 0.5 V 0.1% + 0.5 V 0.5% + 0.3 V
Frequency 0.01% + 10 μHz 0.01% + 10 μHz 0.01% + 10 μHz
For a sine wave with a resistive load at 0 ° to 40 °C, within an output frequency range of 45 Hz to 1000 Hz, and in AC coupled mode
after a 30 minute warm-up unless otherwise noted.
1. Product may be operated between DC and 45 Hz subject to certain deratings. Measurements may be extended to 4.5 Hz at full accuracy only by selecting a
digitization rate of 250 μs per point. Frequency content of the measured signal must be limited to 4 kHz or less to avoid aliasing effects.
Specifications