Datasheet
08 | Keysight | 6800C Series AC Power Source/Analyzers, 375-1750 VA - Data Sheet
Specifications (continued)
Supplemental characteristics
(Non-warranted characteristics determined
by design and useful in applying the product)
6811C 6812C 6813C
Average measurement resolution
rms voltage 10 mV 10 mV 10 mV
rms current 2 mA 2 mA 2 mA
Programmable output impedance
Resistance 0 – 1 Ω 0 – 1 Ω 0 – 1 Ω
Inductance 20 μh – 1 mh 20 μh – 1 mh 20 μh – 1 mh
Remote sense capability Up to 1 Vrms can be dropped
across each load lead
Up to 1 Vrms can be dropped
across each load lead
Up to 1 Vrms can be dropped
across each load lead
Isolation to ground 300 Vrms/425 VDC 300 Vrms/425 VDC 300 Vrms/425 VDC
Net weight 29.1 kg (64.2 lb) 29.1 kg (64.2 lb) 30.1 kg (66.4 lb)
Shipping weight 33.59 kg (74.05 lb) 33.59 kg (74.05 lb) 34.59 kg (76.26 lb)
AC Input Ratings 6811C 6812C 6813C
Voltage range (VAC)
*default factory setting 87 to 106 VAC
*104 to 127 VAC
87 to 106 VAC
*104 to 127 VAC
174 to 220 VAC
*191 to 254 VAC
174 to 220 VAC 174 to 220 VAC
191 to 254 VAC 191 to 254 VAC
Maximum input current (rms)
(Measured at low line)
12 A (100 VAC) 28 A (100 VAC) 22 A (200/208 VAC)
10 A (120 VAC) 24 A (120 VAC)
7.5 A (200/208 VAC) 15 A (200/208 VAC) 20 A (230 VAC)
6.5 A (230 VAC) 13 A (230 VAC)
Input power (max)
(Measured at high line)
1000 VA/700 W 2500 VA/1400 W 3800 VA/2600 W
Input frequency 47 to 63 Hz 47 to 63 Hz 47 to 63 Hz
For a sine wave with a resistive load at 0 ° to 40 °C, within an output frequency range of 45 Hz to 1000 Hz, and in AC
coupled mode after a 30 minute warm-up unless otherwise noted.
Supplemental characteristics for all model numbers
Size: 425.5 mm W x 132.6 mm H x 574.7 mm D (16.75 in x 5.25 in x 22.6 in)