Input coupling
DC, AC (10 Hz cutoff frequency)
Input impedance/capacitance
1 MΩ ± 2%, 16 pF ±3 pF
Input sensitivity range
4
500 μV/div to 10 V/div
Standard probes
N2142A 1/10 switchable 75 MHz (2 included in EDUX1052A/EDUX1052G)
N2140A 1/10 switchable 200 MHz (2 included
in DSOX1202A/DSOX1202G)
N2140A 1/10 switchable 200 MHz (4 included in DSOX1204A/DSOX1204G)
Probe attenuation factor
0.1X to 10,000X in 1-2-5 sequence; (20 dB to +80 dB in 0.1 dB steps)
Hardware bandwidth limits
Approximately 20 MHz (selectable)
Vertical resolution
8 bits
Invert signal
Selectable
Maximum input voltage
150 Vrms, 200 Vpk
DC vertical accuracy
± [DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
DC vertical gain accuracy
1
+3% full scale ( 10 mV/div)
+4% full scale (< 10 mV/div)
DC vertical offset accuracy
± 0.1 div ± 2 mV ± 1% of offset setting
Skew
Channel to channel: 1 ns (without deskew)
Channel to external: 2 ns (without deskew)
Offset range
500 uV/div to 200 mV/div: +2 V
> 200 mV/div to 10 V/div: +100 V
1. Denotes warranted specifications; All others are typical. Specifications are valid after a 30-minute warm-up period and from ± 10 °C user calibration temperature.
2. Bandwidth specifications apply for 1 mV/div to 10 V/div vertical settings. Bandwidth at the 500 μV/div vertical setting is limited to 20 MHz.
3. Half-channel operation on a 2-channel model refers to two-channel operation when using channel-1 or channel-2 AND channel-3 or channel-4.
4. 500 μV/div is a 2X digital magnification of 1 mV/div setting.
EDUX1052A/EDUX1052G
DSOX1202A/DSOX1202G
DSOX1204A/DSOX1204G
Bandwidth (3 dB)
1, 2
50 MHz
70 MHz
70 MHz
100 MHz (option D1202BW1A)
100 MHz (option D1200BW1A)
200 MHz (option D1202BW2A)
200 MHz (option D1200BW2A)
Calculated rise time (10 to 90%)
7 ns
5 ns (70 MHz base model)
5 ns (70 MHz base model)
≤ 3.5 ns (with 100 MHz option)
≤ 3.5 ns (with 100 MHz option)
≤ 1.7 ns (with 200 MHz option)
≤ 1.7 ns (with 200 MHz option)
Input channels
2
2
4
Maximum sample rate
1 GSa/s (all channels)
2 GSa/s (all channels)
1 GSa/s (if ext. trigger is displayed)
2 GSa/s (one- or half-channel
3
operation)
1 GSa/s (three- or four-channel operation)
Maximum memory depth
200 k points (all channels)
2 M points (all channels)
1 M points (if ext. trigger is displayed)
2 M points (one- or half-channel
3
operation)
1 M points (three- or four-channel operation)
Waveform update rate
100,000 waveforms/sec
200,000 waveforms/sec